Output Delay Block
One delay block is available for each output channel. This block functions the same as
the mic/line input delay block (see
configuring the output delay block).
Output Filter Block
One filter block is available for each output channel. This filter block functions the same as
the input filter block, except that there are 10 slots for filters instead of 5 (see
Block
on page 25 for information on configuring output filters).
Output Dynamics Block
One dynamics block is available for each output channel. This block functions the same as
the input dynamics block (see
configuring the output dynamics block).
Output Attenuation Block
Double-click the output
Figure 86.
The
Attenuation
Figure 87.
Output Name — This name changes to match the default or user defined output name.
1
Output Attenuation Fader — Click and drag the trim fader to provide up to 100 dB of
2
attenuation. Click the trim fader and use the <
fader up or down in 1 dB steps.
Output Attenuation Text Box — Allows the user to enter a gain or attenuation value in
3
0.1 dB steps.
dBFS Meter — Provides post-attenuation and pre-mute a readout of the output signal
4
level.
Input Delay Block
Input Dynamics Blocks
block to open the
Attenuation
Output Attenuation Block
dialog box provides attenuation control for the selected output.
Output Name
1
Output Attenuation Fader
2
Output Attenuation Text Box
3
dBFS Meter
4
dBFS Text Readout
5
Attenuation Dialog Box
on page 35 for information on
on page 30 for information on
dialog box.
Attenuation
Polarity Button
6
Mute Button
7
OK Button
8
Cancel Button
9
> or <
Up Arrow
Down Arrow>
XMP 240 C AT • DSP Configurator Software
Input Filter
to adjust the
54
Need help?
Do you have a question about the XMP 240 C AT and is the answer not in the manual?