Stylus Pro 5000
4.2.2 Front Housing Removal
1. Remove the upper housing. (See Section 4.2.1.)
2. Remove the control panel cable from the connector on the control
panel board.
3. Remove 2 screws (CBS, 3×6) securing the control panel grounding
plate to the paper eject frame. (See Figure 4-8.)
2 CBS screws(3×6)
Front Housing
Figure 4-8. Front Housing Removal
Control Panel
Cable
Control Panel
Grounding Plate
4. Use a standard screwdriver to release 2 hooks securing the front
housing. The hooks are on the bottom front of the printer, one on each
side. (See Figure 4-9.)
5. Remove the front housing.
Hook
Figure 4-9. Front Housing Removal (Bottom view)
Chapter 4 Assembly and Disassembly
4-5