Parallel - Epson Stylus Pro 5000 Service Manual

Hide thumbs Also See for Stylus Pro 5000:
Table of Contents

Advertisement

Stylus Pro 5000
PARALLEL INTERFACE
Table 1-10. Compatibility Mode
Item
Transmission mode
8-bit parallel, IEEE-1284 compatibility mode
Synchronization
By STROBE pulse
Handshaking
By BUSY and ACKNLG signal
Logic Level
TTL compatible level (IEEE-1284 Level 1
device)
Adaptable connector
57-30360 (Amphenol) or equivalent
Note 1: Use a twisted-pair cable.
Note 2: The BUSY signal is set high when the /ERROR signal is low or
the PE signal is high. The BUSY signal remains high until all
these signals return to their normal state.
The BUSY signal is high:

During data entry
When the input data buffer is full


When the /INT signal is low, or during hardware initialization
During a printer error (See Error Conditions)


When the parallel interface is not selected
The ERROR signal is low when there is a:
Printer hardware error (fatal error)


Paper out error

Paper jam error

Ink out error
Note: The PE signal is high during a paper-out error.
Description
Table 1-11. Nibble Mode
Item
Transmission mode
IEEE-1284 nibble mode
Synchronization
Refer to IEEE-1284 specification
Handshaking
Refer to IEEE-1284 specification
Signal level
TTL level (IEEE-1284 level 1 device)
Adaptable
57-30360 (Amphenol) or equivalent
connector
Data transfer timing Refer to IEEE-1284 specification
Data requests
When the printer receives the hexadecimal
values 00H or 04H, the printer responds in the
following manner:
00H:
The printer enters reverse channel
mode, allowing data to be sent to the
host.
04H:
The printer sends the device ID to the
host; the device ID consists of the
following strings:
Note: [00H] denotes a hexadecimal value of
zero. The model value depends on the
EEPROM setting.
Chapter 1 Product Description
Description
MFG
:
EPSON
CMD :
ESCPL2, BDC
Model :
Stylus[SP]Pro[SP]5000;
CLS
:
PRINTER
1-8