Input Data Buffer; Electrical Specifications - Epson Stylus Pro 5000 Service Manual

Hide thumbs Also See for Stylus Pro 5000:
Table of Contents

Advertisement

Stylus Pro 5000
Table 1-8. Magenta and Cyan Ink Cartridges
Item
Type
Magenta and Light Magenta ink cartridge
(part no. S020143)
Cyan and Light Cyan ink cartridge (part no. S020147)
Print capacity
3000 pages on A4 paper (360 dpi, 5% coverage)
Lifetime
Sealed: 2 years from production date.
Installed: Six months at 77 °F (25 °C)
Transit: 22 F to 140 F (30 C to 60 C); 120 hours
Environmental

at 140 F (60 C); one month at 104 F (40 C)
conditions
Stored in package: 22 F to 104 F (30 C to

40 C); one month at 104 F (40 C)
Installed: 4 F to 104 F (20 C to 40 C); one

month at 104 F (40 C)
Dimension
1.38 in. (W) x 5.54 in. (D) x 4.14 in. (H)
[35.1 mm (W) x 140.9 mm (D) x 105.3 mm (H)]
Weight
Approximately 0.44 lb. (200g)
Notes:
1. Do not refill or reuse cartridges; they are consumable items.
2. To use ink that is frozen [below 5  F (  15  C)], let it defrost for at least 3
hours at room temperature.

INPUT DATA BUFFER

6KB

ELECTRICAL SPECIFICATIONS

120 V version
Rated voltage:
AC 120 V
Input voltage range:
Rated frequency range:
Input frequency range:
Specifications
AC 99 - 132 V
50 - 60 Hz
49.5 - 60.5 Hz
Rated current:
Power consumption:
Insulation resistance:
Dielectric strength:
Sneak current:
220-240 V version
Rated voltage:
AC 220 - 240 V
Input voltage range:
Rated frequency range:
Input frequency range:
Rated current:
Power consumption:
Insulation Resistance:
Dielectric strength:
RELIABILITY
Total print volume:
75,000 pages (A4 or Letter size)
Printhead life:
2000 million dots/nozzle
Chapter 1 Product Description
1.0 A (Max. 1.6 A)
Energy Star compliant
Approx. 32 W (ISO/IEC 10561 Letter
pattern)
Energy Star compliant
10 M minimum (between AC line and
chassis, DC 500 V)
AC 1000 V rms. 1 minute or AC 1200 V rms.
1 second (between AC line and chassis)
Less than 0.25 mA
AC 198 - 264 V
50 - 60 Hz
49.5 - 60.5 Hz
0.5 A (Max. 0.8 A)
Approx. 32 W (ISO/IEC 10561 Letter
pattern)
Energy Star compliant
10 M minimum (between AC line and
chassis, DC 500 V)
AC 1500 V rms. 1 minute (between AC line
and chassis)
1-5

Advertisement

Table of Contents
loading

Table of Contents