IMPORTANT

Before installing compression spring
(0.98), put some lock-tite on the left
paper feed roller lever.
The compression springs attached to the

left and right paper feed roller levers are
not interchangeable.
17. Remove 1 e-ring (4, F/Uc) from the paper feed mounting shaft. (See
Figure 4-132.)
18. Remove the paper feed mounting shaft. (See Figure 4-133.)
Paper Feed Mounting Shaft
Figure 4-133. Paper Feed Mounting Shaft Removal
19. Remove 1 e-ring (2, F/Uc) from the curler transmission shaft through
the cutout in the frame. (See Figure 4-134.)
E-ring (2, F/Uc)
Figure 4-134. Releasing the Curler Transmission Shaft
20. Remove the curler transmission shaft. (See Figure 4-135.)
Curler Transmission Shaft
Figure 4-135. Curler Transmission Shaft Removal