Calibration and Testing
7. Remove the Recycler from the RT Transport.
8. Lift the Front Transport to block Note Position
Sensor 1 and 2.
Figure 6-112 Note Position
Figure 6-112 Note Position Sensor 1 - 3 Test 5
9. Cover the Note Position Sensor 3 with a
Banknote.
Figure 6-113 Note Position
Figure 6-113 Note Position Sensor 1 - 3 Test 6
10. The RT/RQ Unit Status LED will be lit at Cyan
when the Sensors function properly.
11. Set the UBA Pro DIP Switch #8 to
test.
Note Position Sensor A - C Test
(RT Transport)
To run the Note Position Sensor A - C Test on the
RT Transport side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-114).
Figure 6-114 Note
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
Figure 6-114 Note Position Sensor A - C
Test (RT Transport) 1
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
to end the
ON
4
5
6
7
8
3. Set the DIP Switches of the RT/RQ Unit as below
(Figure 6-115).
Figure 6-115 Note
DIP Switches #1, #4 ON
ON
1
2
3
Figure 6-115 Note Position Sensor A - C
Test (RT Transport) 2
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-116 Note Position
Figure 6-116 Note Position Sensor A - C
Test (RT Transport) 3
6. To start the Test, set the UBA Pro DIP Switch #8
to
(Figure 6-117).
OFF
Figure 6-117 Note
DIP Switch #8 OFF
ON
1
2
3
Figure 6-117 Note Position Sensor A - C
Test (RT Transport) 4
7. Remove the Recycler from the RT Transport to
block the Note Position Sensor A through C.
Figure 6-118 Note Position
Figure 6-118 Note Position Sensor A - C
Test (RT Transport) 5
8. The RT/RQ's Status LED will be lit at Magenta
when the Sensors function properly.
9. Set the UBA Pro DIP Switch #8 to
test.
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 3
Section 6
4
5
6
7
8
Green
ON
OFF
4
5
6
7
8
to end the
ON