Note Position Sensor A - C Test (Rt Transport) - JCM GLOBAL UBA Pro RT Series Operation And Maintenance Manual

Banknote recycler
Table of Contents

Advertisement

Calibration and Testing
7. Remove the Recycler from the RT Transport.
8. Lift the Front Transport to block Note Position
Sensor 1 and 2.
Figure 6-112 Note Position
Figure 6-112 Note Position Sensor 1 - 3 Test 5
9. Cover the Note Position Sensor 3 with a
Banknote.
Figure 6-113 Note Position
Figure 6-113 Note Position Sensor 1 - 3 Test 6
10. The RT/RQ Unit Status LED will be lit at Cyan
when the Sensors function properly.
11. Set the UBA Pro DIP Switch #8 to
test.
Note Position Sensor A - C Test 
(RT Transport)
To run the Note Position Sensor A - C Test on the
RT Transport side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-114).
Figure 6-114 Note
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
Figure 6-114 Note Position Sensor A - C
Test (RT Transport) 1
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
to end the
ON
4
5
6
7
8
3. Set the DIP Switches of the RT/RQ Unit as below
(Figure 6-115).
Figure 6-115 Note
DIP Switches #1, #4 ON
ON
1
2
3
Figure 6-115 Note Position Sensor A - C
Test (RT Transport) 2
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-116 Note Position
Figure 6-116 Note Position Sensor A - C
Test (RT Transport) 3
6. To start the Test, set the UBA Pro DIP Switch #8
to
(Figure 6-117).
OFF
Figure 6-117 Note
DIP Switch #8 OFF
ON
1
2
3
Figure 6-117 Note Position Sensor A - C
Test (RT Transport) 4
7. Remove the Recycler from the RT Transport to
block the Note Position Sensor A through C.
Figure 6-118 Note Position
Figure 6-118 Note Position Sensor A - C
Test (RT Transport) 5
8. The RT/RQ's Status LED will be lit at Magenta
when the Sensors function properly.
9. Set the UBA Pro DIP Switch #8 to
test.
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 3
Section 6
4
5
6
7
8
Green
ON
OFF
4
5
6
7
8
to end the
ON