Dip Switch Test - JCM GLOBAL UBA Pro RT Series Operation And Maintenance Manual

Banknote recycler
Table of Contents

Advertisement

Calibration and Testing

DIP Switch Test

To test the RT/RQ Unit DIP Switch's performance,
proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-80).
Figure 6-80 DIP
DIP Switches #1, #2, #5, #8 ON
ON
1
2
3
Figure 6-80 DIP Switch Test 1
3. Set the DIP Switches of the RT/RQ Unit as below
(Figure 6-81).
Figure 6-81 DIP
DIP Switch #6 ON
ON
1
2
3
Figure 6-81 DIP Switch Test 2
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-82 DIP Switch Test 3
Figure 6-82 DIP Switch Test 3
6. To start the Test, set the UBA Pro DIP Switch #8
to
(Figure 6-83).
OFF
Figure 6-83 DIP
DIP Switch #8 OFF
ON
1
2
3
Figure 6-83 DIP Switch Test 4
7. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-84).
Figure 6-84 DIP
DIP Switches #1, #3, #5, #7 ON
ON
1
2
3
Figure 6-84 DIP Switch Test 5
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
4
5
6
7
8
4
5
6
7
8
Green
ON
OFF
4
5
6
7
8
4
5
6
7
8
8. The UBA Pro
Green
when the RT/RQ DIP Switches function properly.
Figure 6-85 DIP
Figure 6-85 DIP Switch Test 6
9. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-86).
Figure 6-86 DIP
DIP Switches #2, #4, #6, #8 ON
ON
1
2
3
Figure 6-86 DIP Switch Test 7
10. The UBA Pro
Red
the RT/RQ DIP Switches function properly.
Figure 6-87 DIP
Figure 6-87 DIP Switch Test 8
11. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-88).
Figure 6-88 DIP
DIP Switches All OFF
ON
1
2
3
Figure 6-88 DIP Switch Test 9
12. The UBA Pro
Green
turn on when the RT/RQ DIP Switches function
properly.
Figure 6-89 DIP
Figure 6-89 DIP Switch Test 10
13. Set the UBA Pro DIP Switch #8 to
test.
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 1 9
Section 6
Status LED will turn on
Green
4
5
6
7
8
Status LED will turn on when
Red
4
5
6
7
8
and
Red
Status LEDs will
Green
Red
to end the
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uba pro rq series