Section 1
†††
Recycler Capacity
Interfaces:
*. The Banknotes accepted on the second attempt are included. The Acceptance Rate Test was conducted on more than 100 Banknotes. Refer to the "Software Information
Sheet" for each Country's Acceptance Rate parameters.
†. Refer to the specific Country's Barcode Ticket Specification for more details.
‡. Excludes the time lag associated with Host Communication (Power Supply: +24V DC ±5%, Temperature: 25º C ±5º C).
**. The average per note when 10 notes are inserted.
††.The average per note when 10 notes are collected.
‡‡.A key and lock are not included (A tang is provided). Refer to "Cash Box Lock Installation" on page 2-3 for the installation. (2 Key Hole Caps are fitted in place to cover existing
holes when shipped).
***.The number of Polymer Banknotes stacked depends on the Banknote's condition and denomination.
†††.150mm New Banknote Only

Environmental Specifications

Operating Temperature:
Storage Temperature:
Relative Operating Humidity:
Relative Storage Humidity:
Visible Light Sensitivity:
Installation:
100
90
80
70
60
50
40
30
20
10
0
0
5

Electrical Specifications

Supply Voltage:
Current Consumption:
*. Measured on a new and factory default RQ Unit.

Structural Specifications

Weight Empty:
Mounting:
Outside Dimensions: Refer to "Unit Dimensions" on page 1-9 of this Service Manual Section.
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
Table 1-5 RT/RQ Technical Specifications (Continued)
RT Unit: Max. 60 Notes (Max. 30 Notes x 2 Drums)
:
RQ Unit: Max. 120 Notes (Max. 30 Notes x 4 Drums)
USB (USB Specification Rev. 2.0 Compliance) (Full Speed/12Mbps)
Photo-Coupler Isolation
RS232C
cc-Talk
Table 1-6 RT/RQ Environmental Specifications
5ºC to +50ºC (41ºF to 122ºF) *Depends on hydrothermal conditions
-20ºC to +60ºC (-4ºF to 140ºF) *Depends on hydrothermal conditions
15%RH to 85%RH (non-condensing)
30%RH to 85%RH (non-condensing)
Avoid contact with direct Sunlight
(Interior lighting must be incandescent with a Radiant Angle of 15 Degree or more having an
illumination index of 3000 Lux or less)
Indoors Only
Hydrothermal Condition Table
Allowable
Operating Temperature
and Relative Humidity Range
10
15
20
25
30
35
Temperature [°C]
Table 1-7 RT/RQ Electrical Specifications
24V DC (±5%)
Standby: 0.4A
Operation: 2.0A
Peak: 3.8A
Table 1-8 RT/RQ Structural Specifications
RT (with SH2 Box): 8kg (17.63lbs)
RQ (with SH2 Box): 11.4kg (25.13lbs)
Horizontal, 0 degrees, ±0 degrees angle
(Stacking Up (SU) installation is available. Refer to "Installation Procedure" on page 2-1.)
35ºC/85%RH
50ºC/40%RH
5ºC/40%RH
15ºC/15%RH
40
45
50
55
60
(6A or higher Recommended)
© 2020, JAPAN CASH MACHINE CO., LTD.
1 - 8