Calibration and Testing
JCM Tool Suite Standard Edition
Modes
The following two (2) mode feature types exist in
the "
JCM Tool Suite Standard Edition
Normal Mode
Test Mode
"
" (DIP Switches All OFF) is a
Normal Mode
mode designed to provide the UBA Pro Operating
Software to be downloaded. 
The "
" contains three (3) available
Service Mode
choices shown in Figure 6-9
(for downloading software)
Download
(for observing log data)
Statistics
(for ICB settings, Not supported by the
Utility
RT/RQ)
Figure 6-9 Normal Mode Selection
Figure 6-9 Normal Mode Selection
"
" (DIP Switch #8
Test Mode
designed to perform Calibration and Performance
Testing. The "
Service Mode
available choices in its Pull-down Menu shown in
Figure
6-10a
as follows:
(for downloading software)
Download
(for observing log data)
Statistics
Sensor Adjustment
Performance Test
(for ICB settings, Not supported by the
Utility
RT/RQ)
Figure 6-10 Test Mode Selection
Figure 6-10 Test Mode Selection

Software Download

The following two (2) procedures are available to
download the Software Program with a PC (JCM
Tool Suite Standard Edition):
The Software Program is loaded on the Unit
(Upgrade)
The Software Program is not loaded on the Unit
(Initial) (e.g., after replacing the CPU Board)
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
" package:
a
as follows:
a
) is a mode
ON
" contains five (5)
(for calibration)
(for performance testing)
a
To download the Software Program, proceed as
follows:
1. Remove electrical power.
2. Set the RT/RQ's DIP Switches to
3. When upgrading the Software, set the UBA Pro's
DIP Switches as below (Figure 6-11).
Figure 6-11 Software Download
DIP Switches All OFF (Normal Mode)
ON
1
2
3
or
DIP Switch #8 ON (Test Mode)
ON
1
2
3
Figure 6-11 Software Download (Upgrade) 1
When downloading to a Unit (software not previ-
ously installed), set the DIP Switches as below
(Figure 6-12).
Figure 6-12 Software Download (Initial) 1
DIP Switches #6, #7, #8 ON
ON
1
2
3
Figure 6-12 Software Download (Initial) 1
4. Connect the RT/RQ Unit to the PC 
(Refer to Figure 6-1 for the Tool Requirements
and Harness Connector locations).
5. Apply electrical power.
6. The UBA Pro's
be lit.
7. Launch the "
JCM Tool Suite Standard 
" Application.
Edition
8. The Main Screen (Figure 6-13) will appear.
Figure 6-13 Software Download (Upgrade) 2
Figure 6-13 Software Download (Upgrade) 2
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 3
.
All OFF
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
Green
and
Red
Status LEDs will
Section 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uba pro rq series

Table of Contents