Calibration and Testing

Calibration

This section provides instructions for performing a
calibration of the Recycler Sensors.
NOTE: Refer to the UBA Pro Series
Universal Banknote Acceptor Operation
and Maintenance Manual for calibrating the
Sensors on the UBA Pro Unit.

When to Calibrate

Calibration should be performed when one of the
following four (4) conditions occur:
The Unit is disassembled or reassembled.
One of Sensors is removed or replaced.
The UBA Pro Main Board or RT/RQ Main Board is
removed or replaced.
Dirt adheres to the Sensors (Clean the Sensor first.
See "Cleaning Procedure" on page 2-15).
The Banknote Acceptance Rate becomes drastically
degraded.

Sensor Calibration

To calibrate the Recycler Sensors, proceed as 
follows:
1. Remove electrical power.
2. Set each DIP Switch of the UBA Pro and the RT/
RQ as below (Figure 6-21).
Figure 6-21 Sensor Calibration 1
DIP Switch #8 ON
ON
1
2
3
DIP Switches All OFF
ON
1
2
3
Figure 6-21 Sensor Calibration 1
3. Connect the Unit to the PC.
(Refer to Figure 6-1 for the Tool Requirements
and Harness Connector locations).
4. Apply electrical power.
5. The
Green
and
Red
6. Launch the "
JCM Tool Suite Standard Edition
Application.
7. Click and hold-down the "
Down Menu.
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
4
5
6
7
8
4
5
6
7
8
Status LEDs will be lit.
"
" Pull-
Service Mode
8. Select "
Sensor Adjustment
Figure 6-22 Sensor Calibration 2
Figure 6-22 Sensor Calibration 2
9. Confirm that the Sensor Calibration Program
Screen appears (Figure 6-23).
10. Click the "
Sensor Calibration (RC-TQ)
button (Figure 6-23 a).
Figure 6-23 Sensor Calibration 3
a
Figure 6-23 Sensor Calibration 3
11. Click the "
Start
begin the Sensor Calibration.
NOTE: If the Start button is grayed out
(off), check the USB cable connection.
Figure 6-24 Sensor Calibration 4
Figure 6-24 Sensor Calibration 4
© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 5
" (Figure 6-22 a).
"
"
button (Figure 6-24 a) to
a
Section 6
a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uba pro rq series

Table of Contents