Dip Switch Configurations; Denomination Acceptance Settings (Dip Switches At The Front); Sw1 And Sw2 Configurations; Interface And Recycler Settings (Sub Board 2) - JCM GLOBAL UBA Pro RT Series Operation And Maintenance Manual

Banknote recycler
Table of Contents

Advertisement

Section 2

DIP Switch Configurations

Denomination Acceptance Settings (DIP
Switches at the front)
Table 2-1 lists the default Front DIP Switches con-
figurations for the acceptable denominations.
NOTE: Front DIP Switch settings may vary
based on Software. Refer to each Country's
"Software Information Sheet" for making the
proper switch settings.
Table 2-1 Denomination Acceptance Settings
ON
OFF
Switch No.
Switch ON/OFF
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
*
8
OFF
*. Not Applicable (N/A). Never Switched to ON.
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler

SW1 and SW2 Configurations

The UBA Pro CPU Circuit Board contains two (2)
DIP Switches that are located adjacent to one
another. The interface and the Recycler option can
be configured by these Switches (Figure 2-10).
Description
VEND 1 INHIBIT
VEND 1 ACCEPT
Interface and Recycler Settings (Sub
VEND 2 INHIBIT
Board 2)
The SW1 switch equipped on the Sub Board 2 is to
VEND 2 ACCEPT
set an interface RS232C, Photo-Coupler Isolation,
or ccTalk (Table 2-2).
VEND 3 INHIBIT
VEND 3 ACCEPT
VEND 4 INHIBIT
VEND 4 ACCEPT
VEND 5 INHIBIT
VEND 5 ACCEPT
VEND 6 INHIBIT
VEND 6 ACCEPT
VEND 7 INHIBIT
VEND 7 ACCEPT
OFF (Fixed)
*. Refer to the UBA Pro Series Operation and Maintenance Manual for using the
2 - 4
NOTE: Refer to the UBA Pro RC Series
Banknote Recycler Operation and
Maintenance Manual for the Recycler
options.
Figure 2-10 SW1 and SW2 Switches
Bottom View
Figure 2-10 SW1 and SW2 Switches
NOTE: For the USB interface, no need to
configure the SW1 switch.
Table 2-2 Sub Board 2 Interface Settings
SW 1
Front
SW 2
Settings
SW1
-
SW2
UBA Pro unit with a Recycler(s).
© 2020, JAPAN CASH MACHINE CO., LTD.
Installation
SW1
SW2
Back
Description
Photo-Coupler Isolation
RS232C
cc-Talk
USB
To use a UBA Pro Unit
with a Recycler Unit(s)
To use a UBA Pro Unit
*
without a Recycler(s)