Calibration and Testing
7. Remove the Recycler from the RQ Transport to
block the Note Position Sensor D through F.
Figure 6-156 Note Position
Figure 6-156 Note Position Sensor D - F Test
(RQ Transport) 5
8. The RQ Unit's Status LED will be lit at Magenta
when the Sensors function properly.
9. Set the UBA Pro DIP Switch #8 to
test.

Recycler Solenoid Test (RQ Transport)

To run the Recycler Solenoid on the RQ Transport
side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-157).
Figure 6-157 Recycle
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
Figure 6-157 Recycle Solenoid Test
3. Set the DIP Switches of the RQ Unit as below
(Figure 6-158).
Figure 6-158 Recycle
DIP Switches #5, #8 ON
ON
1
2
3
Figure 6-158 Recycle Solenoid Test
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
P/N 960-000213R_Rev.A
UBA Pro RT/RQ™ Series Banknote Recycler
to end the
ON
4
5
6
7
(RQ Transport) 1
4
5
6
7
(RQ Transport) 2
Figure 6-159 Recycle Sole-
Figure 6-159 Recycle Solenoid Test
6. To start the Test, set the UBA Pro DIP Switch #8
to
(Figure 6-160).
OFF
Figure 6-160 Recycle
DIP Switch #8 OFF
ON
1
Figure 6-160 Recycle Solenoid Test
7. The Solenoid will start operating when it func-
tions properly.
NOTE: Confirm the functionality aurally by
the sound that the Solenoid is making
while in the operation.
8. Set the UBA Pro DIP Switch #8 to
test.

Drum 1 Motor Test (RQ Transport)

To run the Recycler Solenoid on the RQ Transport
side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-161).
Figure 6-161 Drum 1
DIP Switches #1, #2, #6, #8 ON
8
ON
1
Figure 6-161 Drum 1 Motor Test (RQ Transport) 1
3. Set the DIP Switches of the RQ Unit as below
(Figure 6-162).
Figure 6-162 Drum 1
DIP Switches #6, #8 ON
8
ON
1
Figure 6-162 Drum 1 Motor Test (RQ Transport) 2
6 - 2 9
Green
ON
(RQ Transport) 3
2
3
4
5
6
(RQ Transport) 4
ON
2
3
4
5
6
2
3
4
5
6