Introduction

Scope of Manual

This instruction manual includes installation and parts information for Fisher ENVIRO-SEAL live-loaded packing
systems (see figure 1). These systems are available for Fisher rotary valves with 12.7 through 88.9 mm (1/2 through
3-1/2 inch) shaft diameters. The system can be used with many rotary valves, as shown in tables 1 and 3. Refer to
appropriate valve and actuator instruction manuals for necessary information relating to the disassembly and
assembly of the valve and actuator. ENVIRO-SEAL packing systems utilize a Belleville (coned-disk) spring system.
Do not install, operate, or maintain the ENVIRO-SEAL packing system, valve, actuator or accessories without being
fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal
injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual,
including all safety cautions and warnings. If you have any questions about these instructions, contact your
sales office
before proceeding.
www.Fisher.com
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
Packing System
Figure 1. Typical ENVIRO-SEAL Packing System
1
1
2
2
3
3
4
11
13
13
13
16
W9058-1
ENVIRO-SEAL System - Rotary Valves
ROTARY
BUTTERFLY
February 2019
Emerson

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Fisher ENVIRO-SEAL

  • Page 1: Table Of Contents

    If you have any questions about these instructions, contact your Emerson sales office before proceeding.
  • Page 2: Valve/Actuator Shaft Coupler

    Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 Table 1. Specifications Applicable Valve Designs Applicable Shaft Diameters Fisher 8510B (single arrangements only), 8560 and See table 3 8532 eccentric disk control valves; A11, A31A, A31D and A41 control valves; V150, V200 and V300 Vee‐Ballt control valves (Series B &...
  • Page 3: Installation

    Therefore, no change should be needed in actuator sizing. If you are changing the packing system material from standard PTFE to ENVIRO‐SEAL graphite or ENVIRO‐SEAL PTFE packing, the packing friction will increase. Contact your Emerson sales office to determine if your existing actuator will be large enough.
  • Page 4: Installing An Enviro-Seal Packing System

    Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 You must remove the actuator from the valve when you install ENVIRO‐SEAL packing systems. To allow proper readjustment of the valve disk position, it is recommended that you remove the valve from the pipeline. Refer to appropriate valve and actuator instruction manuals.
  • Page 5 Instruction Manual ENVIRO-SEAL System - Rotary Valves D101643X012 February 2019 Figure 2. Typical ENVIRO‐SEAL Rotary Packing Arrangements with PTFE Packing for Fisher Vee‐Ball, Eccentric Plug, A41, and 8560 Valves 42B8445‐C SINGLE PTFE PACKING STANDARD DEPTH BOX 14B0095‐A STACKING ORDER PTFE PACKING RINGS 42B8445‐C 42B8445‐C 42B8445‐C...
  • Page 6 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 a. Place one of the packing box rings (key 107) into the packing box. Be sure the packing box ring is properly seated. This does not apply to NPS 3, 4 and 6 CL600 A11 valves. b.
  • Page 7 Instruction Manual ENVIRO-SEAL System - Rotary Valves D101643X012 February 2019 Figure 3. ENVIRO‐SEAL PTFE Packing System for Fisher 8532, A11, A31A and A31D Valves 14B0095‐A STACKING ORDER OF 32B9116‐B PTFE PACKING RINGS NOTES: NOT USED ON VALVES LARGER THAN NPS 12 NOT USED ON A11 NOT USED ON A11 CL600, NPS 3, 4, AND 6 11.
  • Page 8 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 Figure 4. Typical ENVIRO‐SEAL Rotary Packing Arrangements with Graphite Packing for Fisher Vee‐Ball, Eccentric Plug, A41, and 8560 Valves 42B8445-C/DOC GRAPHITE PACKING STANDARD DEPTH BOX 14B0086-A/DOC 42B8445-C/DOC 42B8445-C/DOC STACKING ORDER GRAPHITE PACKING, OUT- GRAPHITE PACKING GRAPHITE PACKING RINGS...
  • Page 9 Instruction Manual ENVIRO-SEAL System - Rotary Valves D101643X012 February 2019 Figure 5. ENVIRO‐SEAL Graphite Packing System for Fisher 8532, A11, A31A and A31D Valves 14B0086‐A STACKING ORDER OF GRAPHITE PACKING RINGS 32B9116‐B NOTES: VALVES WITH SHAFTS LARGER THAN 38.1 mm (1-1/2 INCH) USE 3 GRAPHITE RINGS NOT USED ON VALVES LARGER THAN NPS 12 NOT USED ON A11 VALVES NOT USED ON A11 CL600 NPS 3, 4, AND 6...
  • Page 10 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 Figure 6. Belleville Spring Stacking Order O-RING O-RING BELLEVILLE BELLEVILLE SPRINGS (10) SPRINGS (6) PACKING PACKING FOLLOWER FOLLOWER GRAPHITE GRAPHITE A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐ A41, ECCENTRIC DISK, ECCENTRIC PLUG, AND VEE‐ BALL VALVES: SIZE 12.7 &...
  • Page 11: Other Considerations

    This does not need to be an exact measurement; visual inspection is adequate. If the packing bore does not meet this criteria, however, you should replace the valve or have your Emerson service center repair it.
  • Page 12 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 Table 3. Applicable Valve Sizes Table 3. Applicable Valve Sizes and Shaft Diameters and Shaft Diameters (cont.) VALVE SHAFT DIAMETER VALVE SHAFT DIAMETER VALVE SIZE, PRESSURE VALVE SIZE, PRESSURE VALVE VALVE CLASS Inches...
  • Page 13: Parts Ordering

    107) from the original packing. Discard the 3 mm (1/8‐inch) packing box ring from the retrofit kit. If a replacement packing box ring (long, key 107) is required, refer to the valve instruction manual for parts, or consult your Emerson sales office.
  • Page 14 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 Table 4. Retrofit Kit Included Parts Description Quantity Anti‐blowout follower Jam nut Packing stud or 4 Packing nut or 4 Packing flange Spring pack assembly Spring pack assembly Packing Set Anti‐extrusion washer Packing box ring Cable...
  • Page 15 13B9289X012 14B3985X012 44.5 (1‐3/4) 13B9285X012 13B9286X012 57.2 (2‐1/4) 14B1323X012 14B3978X012 63.5 (2‐1/2) 12B4111X012 12B4116X012 76.2 (3) 14B5651X022 14B5660X022 88.9 (3‐1/2) 14B5729X042 14B5736X042 1. Shaft diameter: Diameter through the packing box. 2. For larger shaft sizes, consult your Emerson sales office.
  • Page 16: Repair Kits

    WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
  • Page 17 12B7783X012 14B3541X042 13B8709X012 76.2 (3) 14B5652X012 14B5656X012 14B3541X062 18A4189X012 88.9 (3‐1/2) 14B5730X012 14B5734X012 14B3541X072 14B5735X012 1. Shaft diameter: Diameter through the packing box. 2. For larger shaft sizes, consult your Emerson sales office. 3. The A11 requires 2 Anti-Extrusion Rings.
  • Page 18 Instruction Manual ENVIRO-SEAL System - Rotary Valves February 2019 D101643X012 A coupler is required for the following valve/actuator combinations when retrofitting an existing A31A or A31D with an ENVIRO‐SEAL packing system. Table 10. Coupler Part Number for Fisher A31A or A31D Valves with Selected Actuators SHAFT DIAMETER, Coupler Valve Size...
  • Page 19 The existing couplers, listed below, can accommodate a retrofit with an ENVIRO‐SEAL packing system. Coupler replacement is not required when retrofitting the valve/actuator combinations listed below. For information about couplers for the A11 CL600 valves, contact your Emerson sales office. Table 11. Coupler Part Number for Fisher A31A or A31D Valves with Selected Actuators...
  • Page 20: D101643X012 February

    Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, ENVIRO-SEAL, and Vee-Ball are marks owned by one of the companies in the Emerson Automation Solutions business division of Emerson Electric Co.