PACSystems™ Industrial Displays User Manual Contents GFK-3138B Jul 2021 Contents Section 1: Introduction ............1 An Introduction to RXi – Industrial Displays ............1 1.1.1 Advantages to RXi - Industrial Displays ............1 RXi - Industrial Monitor ..................3 1.2.1 Primary Technical Features ................ 3 1.2.2 Display Architectural Options ..............
Page 3
PACSystems™ Industrial Displays User Manual Contents GFK-3138B Jul 2021 3.1.1 Jumpers and Connectors Location ............71 3.1.2 I/O and Connectors ................. 72 3.1.3 LED Indicators ..................76 RXi - Panel PC..................... 77 3.2.1 Battery ....................77 3.2.2 I/O and Connectors ................. 78 3.2.3 LED Indicators ..................
Page 4
It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the Emerson products referenced herein.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Section 1: Introduction An Introduction to RXi – Industrial Displays RXi – Industrial Displays are a modular and fanless display portfolio consisting of industrial monitors, web panels, and panel PC options to suit customer visualization and computing needs. The entire portfolio features IP66-rated screens that protect against dust, moisture, and waterjets as well as a range of TFT LCD screen sizes in a 16:9 format: 7”, 10”, 12”, 15”, 19”, 24”.
Page 6
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Screen Chemical Resistances • Acetone • Unleaded Gasoline • Isopropyl Alcohol • Motor Oil • Laundry Detergents • 5% Salt Water • Hydraulic Fluid Skydrol Glove Compatibility RXi Industrial Displays are compatible with a wide variety of PPE, which eliminates the need for a worker to remove gloves to interface with the screens.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Figure 2: Daisy Chaining To enable touchscreen capabilities, the USB cable must be attached from the individual screen back to the IPC. Note: Microsoft Windows limits user input to one touchscreen at a time, even with multiple screens attached to the IPC.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.3.4 Configuration and Setup RXi Industrial Monitor On-Screen Display (OSD) AD Board OSD Functions Figure 4: AD Board OSD Functions Legend Auto-Adjust Up/Left Down/Right Power Menu/Entry Power Indicator Power switch: To turn ON or OFF the power Shift the icon to the left side or shift it up Shift the icon to the right side or shift it down Menu: To enter the OSD menu for related icon and item...
Page 10
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 If unable to exit Burn-in Mode If the RGB is still on the top left corner of the screen, press to enter Miscellaneous and choose Reset, and then select Yes, and press .
Page 11
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Main Menu Picture To access the main menu, push the Menu button on the OSD controls. Figure 6: Picture Menu Options Menu Items Descriptions AutoBacklight Adjusts the brightness of the screen based on the brightness level of the video in use Backlight Adjusts the brightness of the display...
Page 12
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Display Figure 7: Display Menu Options Menu Items Descriptions The screen will calibrate the display to show the best screen AutoAdjust orientation and position H Position Moves the screen left or right (horizontally) V Position Moves the screen up or down (vertically) Disp Rotate...
Page 13
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Input Figure 9: Input Menu Options Menu Items Descriptions Auto Select Automatically displays input from whichever ports are supplying media Manually displays input from DisplayPort port HDMI Manually displays input from HDMI port Audio Figure 10: Audio Menu Options Menu Items...
Page 14
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Other (Menu Item) Figure 11: Other Menu Options Menu Items Descriptions Reset It will reset the values to original/ default values. Menu Time Adjusts the time that the menu will remain on-screen after pressing the menu button.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 RXi - Panel PC The RXi - Panel PC is a modular display portfolio that offers multiple options of separable screens and computing units, which maximize flexibility, performance, and durability. The portfolio ranges from 7" to 24"...
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.4.3 Display Architectural Options The RXi – Panel PC can operate as a stand-alone unit or connect directly with an RXi – Industrial Monitor for dual-screen operation. For more information, please see the RXi – Industrial Monitors Data Sheet. Figure 12: Configuration Introduction...
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.4.4 Drivers Installation Note: Instructions are the same for Panel PC with or without AMD Ryzen. Read and accept the End User License Agreement (Figure 13). Figure 13: End User License Agreement Express Installation There are two installation processes.
Page 19
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Figure 15: Restart Now Custom Installation Customer installation is available to allow users to specify which drivers they want to install. To proceed: 1. Select Custom Install (Figure 16). 2. Select your driver requirements and click Install (Figure 17). 3.
Page 20
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Figure 17: Drivers Selection Figure 18: Restart Now Note: It is strongly encouraged to restart the Panel PC before continuing. Introduction...
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.4.5 Configuration and Setup with RXi – Panel PC Set Brightness in Panel PC Changing the screen brightness of a Panel PC must be done in the BIOS. 1. During startup, repeatedly press the Delete key. 2.
Page 22
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Submenu When “ ” appears on the left of a particular field, it indicates that a submenu that contains additional options are available for that field. To display the submenu, move the highlight to that field and press Enter.
Page 23
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Advanced The Advanced menu allows you to configure your system for basic operation. Some entries are defaults required by the system board, while others if enabled, will improve the performance of your system or allow the user to set some features according to their preference.
Page 24
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Trusted Computing This section is used to configure the Trusted Computing settings. Figure 22: Trusted Computing BIOS Parameter Description Enable or disable BIOS support for a security device. The Operating System will not show a security device. TCG EFI Security Device Support protocol and INT1A interface will not be available.
Page 25
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Wakeup Configuration This section is used to configure the Wakeup ACPI Power Management. Figure 23: Wakeup Configuration BIOS Parameter Description Resume by PME Enable or disable to resume by PME (PCI, PCIe, LAN, etc.) Resume by USB Enable or disable to resume by USB.
Page 26
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 CPU Configuration This section is used to configure the CPU. It will also display the detected CPU information. Figure 24: CPU Configuration BIOS Parameter Description Enable or disable CPU Virtualization. SVM Mode Core Leveling Select the number of cores in the system: Automatic mode, Three cores per...
Page 27
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 IDE Configuration This section is used to configure the IDE Devices. It will also display the detected information. Figure 25: IDE Configuration USB Configuration This section is used to configure the parameters of the USB Device. Figure 26: USB Configuration BIOS Parameter Description...
Page 28
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 NCT61120 Super IO Configuration This section is used to configure the parameters of the system super IO chip. BIOS Parameter Description Enable or disable the serial COM port. Serial Port Enable or disable the RS485 auto flow support.
Page 29
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 NCT 6112D Super IO Features This section is used to configure some control functions of the system super IO chip. Figure 28: NCT 6112D Super IO Features BIOS Parameter Description A WatchDog timer (WDT) is a hardware timer that automatically generates a system reset if the main program neglects to periodically service it.
Page 30
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Network Stack Configuration This section is used to enable or disable network stack settings. The Network Stack Controls LAN1 & LAN2 (Also LAN 3 & LAN4 on large computing module). Figure 29: Network Stack Configuration BIOS Parameter Description...
Page 31
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Chipset This section configures relevant chipset functions. Figure 30: Chipset Screen BIOS Parameter Description OnChip SATA Channel Enable or disable Serial ATA OnChip SATA Type Select OnChip SATA Type: Native IDE, AHCI, or Legacy IDE. SD Mode Enable or disable Secure Digital (SD) Mode configuration.
Page 32
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Boot Configuration Figure 31: Boot Configuration Menu BIOS Parameter Description Select the number of seconds to wait for the setup activation Setup Prompt Timeout key. 65535(0xFFFF) denotes indefinite waiting. This allows you to determine the default state of the numeric keypad.
Page 33
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Hard Drive BBS Priorities Set the order of the legacy devices in this group. Figure 32: Hard Drive BIOS Boot Specification BIOS Parameter Description Launch CSM This field is used to enable or disable to launch of CSM. Boot Option Filter This option controls what device(s) the system will boot to.
Page 34
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Security Figure 33: Security BIOS Parameter Description Administrator Password Set the administrator password. User Password Set the user password. This section is used to configure customizable secure boot Secure Boot Menu settings.
Page 35
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Key Management This section enables experienced users to modify secure boot variables. Figure 34: Key Management BIOS Parameter Description Enable or disable to install factory default secure boot keys when the system is in Default Key setup mode.
Page 36
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Save & Exit Menu Options Figure 35: Menu Options BIOS Parameter Description To save the changes, select this field and then press Enter. A Save Changes and Reset dialog box will appear. Select Yes to reset the system after saving all changes made.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.4.7 Accessing the BIOS (Panel PC with AMD Ryzen) Main The Main menu is the first screen that you will see when you enter the BIOS Setup Utility. BIOS Parameter Description System Choose the system default language.
Page 38
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 AMD Chipset Settings This section configures AMD CBS parameters. Figure 36: AMD Chipset Setting BIOS Parameter Description Ac Loss Control Select Ac Loss Control Method. DRAM ECC Use this option to enable/disable DRAM ECC. The auto will set ECC to enable. Enable This field is used to configure UMA Mode and NB Azalia.
Page 39
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Trusted Computing This section is used to configure the Trusted Computing settings Figure 37: Trusted Computing BIOS Parameter Description Security Device Enable or disable BIOS support for a security device. O.S. will not show a security Support device.
Page 40
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 PCI-E Port Configuration Figure 38: PCI-E Port Configuration BIOS Parameter Description Hotplug Mode To enable/disable Hotplug Mode Control of Mini PCIe. Control(Mini PCIE) Hotplug Mode Control To enable/disable Hotplug Mode Control of M.2-E. (M.2 -E) Dimming Control This section is used to configure displays and dimming.
Page 41
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Advanced Figure 39: Advanced BIOS Parameter Description DP0 Output Mode To enable/disable LCD panel display. DP1 Output Mode To enable/disable rear DP display. Auto Backlight Dimming To dim backlight by TB573D. Minimum Dimming Level Ranges from 1~20%.
Page 42
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 ACPI Configuration This section configures system ACPI parameters. Figure 40: ACPI Configuration BIOS Parameter Description Wake on PCIe Enable/disable integrated LAN to wake the system Wake on RTC from S5 Resume by RTC Alarm after S5 shutdown NCT6112D Super IO This section is used to configure the parameters of the system...
Page 43
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 NCT611D Super IO Configuration Figure 41: NCT611D BIOS Parameter Description WatchDog Timer Unit Select WatchDog Timer Unit by second or minute. Disable the timer by value 0 or set another timeout value to SuperIO WatchDog Timer enable the timer.
Page 44
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Serial Port Console Redirection Figure 42: Serial Port Console Redirection BIOS Parameter Description Enable / disable console direction. Console Redirection Specify how the host computer and the remote one (which the user is using) will exchange data.
Page 45
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Serial Port Console Redirection Figure 43: Serial Port Console Redirection BIOS Parameter Description VT100 – ASCII CharSet VT100+ Extends VT100 to Support color and function keys ANSI VT-UTF8 - Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
Page 46
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Even - Parity bit is 0 if the num of 1’s in the data bits is even. Odd - Parity bit is 0 if the num of 1’s in the data bits is A parity bit can odd.
Page 47
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 CPU Configuration This section is used to configure the CPU. Figure 44: CPU Configuration BIOS Parameter Description Enable or disable the generation of ACPI _PPC, _PSS, and _PCT PSS Support objects.
Page 48
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 USB Configuration This section is used to configure the parameters of a USB device Figure 45: USB Configuration BIOS Parameter Description Legacy USB Support Enable or disable Legacy USB support. This is a workaround for OSes without XHCI hand-off support.
Page 49
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 CSM Configuration Enable or disable CSM options, Option ROM execution settings, etc. Figure 46: CSM Configuration BIOS Parameter Description CSM Support Enable or disable CSM support Introduction...
Page 50
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Network Stack Configuration This section is used to enable or disable network stack settings. Figure 47: Network Stack Configuration BIOS Parameter Description Network Stack Enable or disable the UEFI network stack. When Network Stack is set to enabled, the below settings will be shown.
Page 52
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Secure Boot menu This section is used to configure customizable secure boot settings. Figure 49: Secure Boot Menu BIOS Parameter Description Enable or disable secure boot. Secure Boot features are active if Secure Boot is enabled, Platform Key(PK) is enrolled and the Secure Boot System is in User mode.
Page 53
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Secure Boot menu BIOS Parameter Description Factory Key Provision Install factory default Secure Boot Keys after the platform reset and while the System is in Setup mode. Restore Factory Keys Force System to User mode.
Page 54
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Secure Boot Variables Figure 50: Secure Boot Variables Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2.
Page 55
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Boot Figure 51: Boot BIOS Parameter Description Setup Prompt Timeout Select the number of seconds to wait for the setup activation key. 65535(0xFFFF) denotes indefinite waiting. This allows you to determine the default state of the numeric keypad.
Page 56
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Save & Exit Figure 52: Save & Exit' BIOS Parameter Description Save Changes and To save the changes, select this field and then press <Enter>. A dialog box will Reset appear.
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 RXi - Web Panel An Emerson display that provides the ability to view web-hosted interfaces and dashboards. 1.5.1 Primary Technical Features • Linux Yocto OS Version 4.9.88 • HTML5 Capability 1.5.2...
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 1.5.3 Configuration and Setup of RXi - Web Panel Adjusting Screen Sensitivity TouchTool Steps 1. Open Chromium browser and point to chrome://apps (Figure 54). 2. Select Touch Tools for touchpoint and screen sensitivity adjustment. 3.
Page 59
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Figure 56: Sensitivity Level Ambient Light Sensor (ALS) The RXi Web Panel uses a photodiode to sense the ambient light and in turn, the microcontroller reads the ALS, adjusting the LCD backlight. The ALS function can be switched on or off by the mainboard 1.
Page 60
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Adjusting Screen Brightness 1. Open Chromium browser and point to chrome://apps (Figure 54). 2. Select Brightness Setup from the menu to adjust backlight dimming or ALS on/off control. Note: The manual adjustment bar will only be shown when ALS is off. 3.
Page 61
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 User Password Settings The user/root default password is EMrootroot. Here are instructions to change the password. 1. Click the user password icon. Figure 59: User Password Icon 2. Enter the default (old) and new password then click the Set user password or Set root password button to submit the new password.
Page 62
PACSystems™ Industrial Displays User Manual Section 1 GFK-3138B Jul 2021 Network Setup 1. Open Chromium browser and point to chrome://apps 2. Select Network Setup 3. Assign values to the empty fields to setup your network 4. Click the Setup button to complete the setup. Figure 61: Network Setup Date and Time Settings 1.
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 Size (inch) 7" 10" 12" 15" 19" 24" UL and cUL Information Technology Equipment (UL/CSA 62368-1) UL and cUL Class 1 Division 2: Programmable Controllers for Use in Hazardous Locations (UL/CSA 61010-2-201, UL 121201, CSA C22.2 No.
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 RXi - Panel PC 2.2.1 Panel PC (Base Model) Display Size 7" 10" 12" 15" 19" 24" 1024 x 600 Resolution 1280 x 800 WXGA 1920 x 1080 Full HD Format Widescreen (16:10) Widescreen (16:9)
Page 66
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 Display Size 7" 10" 12" 15" 19" 24" Operating Control Method Touch Projected Capacitive Touch Technology (PCT/PCAP) Touchscreen Multi-touch Touch Sensor (Ten-Point) 2 x 10/100/1000 4 x 10/100/1000 Port 1 Base T Ethernet RJ45 Base T Ethernet RJ45 1 x RS-232 COM Port (5-Pin Connector, Isolated, use 24-16AWG (0.2-1.3mm²),...
Page 67
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 Display Size 7" 10" 12" 15" 19" 24" Specification 11kg 192(W) 267(W) 329.1(W) 410.2(W) 500(W) 600(W) Dimensions 137(H) 186.2(H) 226.8(H) 257.6(H) 315(H) 382(H) (mm) 65(D) 65(D) 66(D) 65(D) 70(D) 71(D) UL and cUL Information Technology Equipment (UL/CSA 62368-1) UL and cUL Class 1 Division 2: Programmable Controllers for Use in Hazardous Locations (UL/CSA 61010-2-201, UL 121201, CSA C22.2 No.
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 2.2.3 Panel PC (with AMD Ryzen) Display Size 7" 10" 12” 15" 19" 24" Resolution 1920 x 1080 Full HD Format Widescreen (16:9) Orientation Landscape 176 (H) / 170 (H) / 170 Reading Angle (°) 178 (H) / 178 (V) 176 (V)
Page 70
PACSystems™ Industrial Displays User Manual Section 2 GFK-3138B Jul 2021 Display Size 7" 10" 12” 15" 19" 24" Maximum Wattage Power 49 W 52 W 50 W 64 W Consumption Front-Side IP66 & Type 4/4X (When Installed to a suitable Wall/Panel) Protection-Class Back-Side IP20...
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 3.1.2 I/O and Connectors DC_IN1 (3.5mm Pitch 1x3 Pin Connector), DC24V power input connector Pin # Power Input Pin1 DC+24V Pin2 Ground Pin3 HDMI (HDMI Input) (HDMI Connector), High Definition Multimedia Interface connector, provides high-quality video and audio input.
Page 77
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 DP1 (Display Port Input) (Display Port Connector), Display Port Interface connector, provide high-quality video and audio input. Signal Name Pin# Pin# Signal Name LANE3- LANE3+ LANE2- LANE2+ LANE1- LANE1+ LANE0- LANE0+ AUX_CHP DP CAB DET...
Page 78
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 CN2 - Reserved (2.0mm 1x4 Pin Header) Pin # Signal Name HOST_I2C_SCL HOST_I2C_SDA HOST_IRQ_OUT CN3 - Reserved (2.0mm 1x4 Pin wafer connector), Reserved for IR receiver Pin # Signal Name 3.3V CN4 (OSD) (2.0mm 1x9 Pin wafer connector), On-Screen Display menu Control connector.
Page 79
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 LVDS Odd CLK- LVDS Odd CLK+ LVDS Odd3- LVDS Odd3+ LVDS Even0- LVDS Even0+ LVDS Even1- LVDS Even1+ LVDS Even2- LVDS Even2+ LVDS Even CLK- LVDS Even CLK+ LVDS Even3- LVDS Even3+ USB D- USB 5V...
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 RXi - Panel PC 3.2.1 Battery The lithium-ion battery powers the real-time clock and CMOS memory. It is an auxiliary source of power when the main power is shut off or disconnected. It is a standard CR2032 battery and is accessible on the bottom of the computing module when separated from the screen (as shown below) Safety Measures •...
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 3.2.2 I/O and Connectors Outside I/O The rear panel I/O port arrangement consists of the following: • 1 power button • 1 24V DC-in 3-pin power connector • 1 DP++ •...
Page 83
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 7. Once power is applied, the unit begins initializing. The first thing to display is the splash screen. Be sure to connect a DC power cord to this 3-pin power connector. Using a voltage out of the range may fail to boot the system or cause damage to the system board.
Page 84
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 Wake-On-USB Keyboard/Mouse The Wake-On-USB Keyboard/Mouse function allows you to use a USB keyboard or USB mouse to wake up a system from the S3 (STR - Suspend To RAM) state. Serial Ports (UART) Serial Connection Function...
Page 85
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 I/O Connectors Serial ATA (SATA) Connector Features • 1 Serial ATA 3.0 port with data transfer rate up to 6Gb/s • Integrated Advanced Host Controller Interface (AHCI) controller The Serial ATA connector is used to connect the Serial ATA device. Connect one end of the Serial ATA data connector to a SATA connector on the other end to your Serial ATA device.
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 3.2.3 LED Indicators Operation Status LEDs (Screen) All RXi Industrial Displays have a tri-color LED built into the screen that provides a visual indication of the operation status. LED State System State Amber, Solid Operating system starting...
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 RXi - Web Panel 3.3.1 Jumpers and Connectors Locations Setting Jumper Functions Before installing the Web Panel, please set the necessary functions following the chart below. Note: To determine Pin 1 of the jumper and port, please observe the marking beside the plug. it will be marked as “1”, a bolded line, or a “△”;...
Page 88
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 Socket Description Connecting Input Power (24V DC-in) To connect to power, follow these steps: 1. Verify that the power cable is not energized. 2. Loosen the screw clamps on the mating power connector. 3.
Page 89
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 USB Socket (USB_OTG1/USB1) USB_OTG1: Conn. Mini-USB, B-Type Female, SMD-5P With DIP 4pin, used to load system firmware Figure 2.6 USB, LAN, and COM Ports USB_OTG1 Pin# Signal Name 5V_USB_OTG USB_OTG_DN USB_OTG_DP USB0_ID USB1: Type-A connector, supports USB devices.
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 Debug Socket (DEBUG1) DEBUG1: Conn. 1.25mm, (DF14 with pointing) SMD-4P, used for debugging information. DEBUG Pin# Signal Name 3P3V_S0_IO UART1_TXD_DEBUG UART1_RXD_DEBUG SD-Card Socket (SD1) SD1: Socket, mini SD/TF Card, 9 pins, SMD, supports SD/TF Card devices. BAT1 Socket (BAT1) BAT1: BAT Socket, BS-10-A1B0J001, 20mm SMT, supports non-chargeable batteries.
Page 91
PACSystems™ Industrial Displays User Manual Section 3 GFK-3138B Jul 2021 Ethernet Port Operation LEDs LED State Operating State Speed Yellow, ON 10/100/1000 Link Green, ON Link Status Activity Hardware...
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Section 4: Installation and Mounting Information Panel Cutout Dimensions 4.1.1 Industrial Monitor The RXi Industrial Monitor can be panel-mounted as presented in Section 4.2, Panel Installation Steps. A Type 4, Type 4X, or IP 66 rating is achieved when mounted to the flat surface of a sufficiently rated enclosure.
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 4.1.2 Panel PC Cutout Dimensions The RXi Panel PC can be panel-mounted as presented in Section 4.3, Mounting to Modular Display. A Type 4, Type 4X, or IP 66 rating is achieved when mounted to the flat surface of a sufficiently rated enclosure.
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Panel Installation Steps Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit Insert the unit into the mounting panel cutout Figure 74: Panel Install View Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure.
Page 96
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 4. Tighten all mounting brackets by hand until the gasket seal contacts the mounting surface uniformly. 5. In a cross pattern around the monitor tighten all mounting clip screws to a torque of 13 to 13.9 in-lbs. (15 to 16kgf-cm) making sure not to overtighten the bracket.
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Mounting to Modular Display Figure 77: 7" Mount Figure 78: 10" Mount Figure 79: 12" Panel Mount Installation and Monting Information...
Page 98
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Figure 80: 15" Panel Mount Figure 81: 19"/24" Panel Mount Figure 82: Panel PC with AMD Ryzen Mount Installation and Monting Information...
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 VESA Mount Figure 83: 7" VESA Mount Figure 84: 10" VESA Mount Installation and Monting Information...
Page 100
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Figure 85: 12" VESA Mount Figure 86: 15" VESA Mount Installation and Monting Information...
Page 101
PACSystems™ Industrial Displays User Manual Section 4 GFK-3138B Jul 2021 Figure 87: 19"/24" VESA Mount Figure 88: Panel PC with AMD Ryzen VESA Mount CAUTION • Tighten the mounting clip screws by hand until the gasket contacts the mounting surface uniformly. •...
PACSystems™ Industrial Displays User Manual Section 5 GFK-3138B Jul 2021 Section 5: Firmware Update Instructions for the RXi-Panel PC and RXi2-LP IPC The following Firmware Update requires the user to use a portable media storage device. Users can deploy to either a DVD or a USB stick. Deploy to DVD (Option 1) 1.
PACSystems™ Industrial Displays User Manual Section 5 GFK-3138B Jul 2021 Recover from Image 1. During startup, open the boot menu by repeatedly pressing F7. 2. Under the boot menu, select the recovery image as your boot option. 3. Once you have selected the correct boot option, a Windows PE environment will begin to boot. 4.
Page 104
PACSystems™ Industrial Displays User Manual Section 5 GFK-3138B Jul 2021 2. Folder Options: In C:\Windows the file properties of the release notes file are set to hidden, you must change the file browsing settings in Folder Options to see the file. Figure 90: Folder Options 3.
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 Section 6: RXi Panel PC Windows Activation Procedure The preloaded Windows 10 IOT Enterprise image on Panel PC is not activated by default. The product key is present on the rear of the Panel PC backing module to activate Windows 10 IOT Enterprise. Activate a Windows 10 IoT Enterprise LTSC device Using an Internet Connection NOTICE...
Page 106
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 1. Find the Product Key Sticker that is present on the rear side of the Panel PC backing module as shown in (Figure 93). Figure 93: Product Key Sticker 2. Part of the Product Key may be covered with gray scratch ink. Remove (scratch) the ink layer to reveal the Product Key as shown in (Figure 94).
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 Activate a Windows 10 IoT Enterprise LTSC Device Using a Telephone 1. On the device, open a command prompt as the administrator. 2. Navigate to the <system drive>:\Windows\System32 with folder type slmgr.vbs /ipk XXXXX- XXXXX-XXXXX-XXXXX-XXXXX.
Page 108
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 5. After step 2, a message display stating that the Product Key was installed successfully. Click OK to proceed. Figure 98: Windows Script Host 6. Press the Win+R keys to open Run, then type: SLUI 4 and click on OK. Figure 99: Run the SLUI 4 Command Note: There is a space between SLUI and 4.
Page 109
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 7. Select your country or region and click Next. It navigates to next page where we can see Installation ID. Figure 100: Select Country or Region 8. Call the Microsoft Product Activation Center. (The phone number is provided based on the selected region.) Proceed through the automated menu and answer a few questions about the Windows activation.
Page 110
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 10. The phone activation system will provide the user with a 48-digit Confirmation ID. Enter the Confirmation ID as seen in (Figure 102). Figure 102: Confirmation ID 11. Once the Confirmation ID has been entered, click the Activate Windows button. 12.
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 Section 7: Firmware Update Instructions for the RXi - Web Panel 1. Locate the SW1 dip switch. Figure 104: SW1 Dip Switch 2. Change SW1 1 to ON to enable download mode. Figure 105: SW1 Switch Toggled to ON Firmware Update Instructions for the RXi - Web Panel...
Page 112
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 3. Connect a Micro USB Cable from your desktop/laptop PC (running windows operating system) to the web panel in the OTG port on the Web Panel. Figure 106: OTG Port Location 4.
Page 113
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 5. If a USB connection is detected, you will see the HID-Compliance device as shown in the following picture, then click Start to update the Web Panel firmware. Figure 108: HID-Compliant Device Firmware Update Instructions for the RXi - Web Panel...
Page 114
PACSystems™ Industrial Displays User Manual Section 6 GFK-3138B Jul 2021 6. Upon completion of the update, you will see 1 displayed under Successful Operations. Click Stop and Exit, then Power-off Web Panel. Figure 109: Successful Operations 7. Adjust SW1 1 back to Off for normal operation mode. Figure 110: SW1 Toggled to OFF 8.
Note: If the product is purchased through an Authorized Channel Partner, please contact the seller directly for any support. Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use, or maintenance of any product.