Standard Muting Mode/Exit-Only Muting Mode With Y-Joint Plug - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Input/Output Circuit and Applications

6-2-2-2. Standard Muting Mode/Exit-Only Muting Mode with Y-Joint Plug

[Wiring Example]
F39-JGR3K-L and
F39-JG
B-L
PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.)
A1, A2, B1, B2: Muting sensor (E3Z-R†6)
Function
EDM
Interlock
Operating Range
Selection
Standard Muting Mode
Exit-Only Muting Mode
External Test not used
Optical Synchronization
Timing chart
Unblocked
Blocked
MUTE A
MUTE B
OSSD
• When using the Y-Joint Plug/Socket Connector (F39-GCNY2), the following functions are not available.
- External Test
- Operating Range Selection by wiring
- Wired Synchronization
• When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused. Also refer to
F3SG-SR
328
User's Manual
F39-JGR3K-D and
F39-JG
B-D
F39-GCNY2
1
2
IN
IN1
IN2
Safety controller
PLC *2
*3 *4
DIP switch
EDM Disabled (factory default setting)
-
Auto Reset (factory default setting)
-
Long (factory default setting) *7
-
When not using the Intelligent Tap or the SD Manager 3, perform wiring according to the wiring diagram.
N/A
N/A
N/A
Connect the wires according to the diagram above.
*1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC
and a safety controller of PNP or NPN type according to the system of your application.
*2. When connecting to the PLC, the output mode must be changed with the SD Manager 3
according to your application. Refer to Chapter 4 Setting with SD Manager 3 for more
information on setting this function by the SD Manager 3.
*3. Refer to 6-3. Connectable Safety Control Units for more information.
*4. The safety controller and the F3SG-SR must share the power supply or be connected to
the common terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. When using the Exit-Only Muting, set the function with the SD Manager 3, restore the
settings to the F3SG-SR, and perform wiring according to the wiring diagram.
*7. To set the Short mode, set the function with the DIP Switches on the Intelligent Tap or
the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring according to
the wiring diagram.
Intelligent Tap
2
B1
B2
Reflector
Emitter
A1
Reflector
Receiver
Reflector
1
Wiring for NPN *1
24 VDC
*5
: Indicates a switch position
Setting
SD Manager 3
[External device monitoring] : Disable *6
[Start interlock] : Disable
[Restart interlock] : Disable *6
[Operating Range Selection] : Long mode *6
[Muting] : Enable
[Muting mode] : Standard Muting (Installation
Example1/2) *6
[Muting] : Enable
[Muting mode] : Exit-Only Muting *6
6-2-1-1. 
5-4-4. 
Functional Earth Connection for more information.
Needed *6
(E39-R1S)
Reflector
A2
24 VDC
Auto Reset Mode with