Setting with Intelligent Tap
*2 If the setting value is not an allowable one, the setting is invalid. The following cases are judged as
invalid.
•All beams have been configured as a Fixed Blanking zone (including allowable beams).(Fig. 1)
•All beams except the beams at both ends have been configured as a Fixed Blanking zone. (Fig. 2)
•End beams (synchronization beams) have been configured as a Fixed Blanking zone at the same
time. (Primary sensor in Optical Synchronization only) (Fig. 3)
•The Teach-in must be performed with at least 1 beam being blocked.(Fig. 4)
•When the Teach-in is performed for more than one Fixed Blanking zones, there must be at least 3
beams between the blocking objects.(Fig. 5)
•Four or more areas have been configured as Fixed Blanking zones for one channel.
Upper
Lower
Indicator status of the F3SG-SR when Teach-in setting is valid or invalid
Teach-in setting is valid
LED Indicator
SEQ
CFG
ABI
(6) Restart
<When operating the F3SG-SR with the Intelligent Tap not connected>
When completing the Teach-in setting, power off the F3SG-SR and remove the Intelligent Tap. Then
restart the F3SG-SR.
<When operating the F3SG-SR with the Intelligent Tap connected>
When completing the Teach-in setting, power off the F3SG-SR and set the DIP Switch Position 1 at
OFF (Unlock). Then restart the F3SG-SR.
There are two ways to restart.
• Power cycling
• Pressing and holding reset switch (for 1 s or longer): Set the DIP Switch Position 1 at OFF (Unlock).
(If restarting the F3SG-SR with the DIP Switch Position 1 set at ON (Lock), the configured zone will
be invalid. In this case, try the steps again from (4).)
After the restarting, the F3SG-SR waits for the Backup process of the settings. Perform the Backup
process. After the Backup process is complete, the power off the F3SG-SR and set the DIP Switch
Position 1 at ON (Lock). Check if the DIP Switch Positions 2 to 8 and other settings are configured as
intended, and then restart the F3SG-SR. After the F3SG-SR is restarted, the check if the Fixed
Blanking zone and other settings are properly configured.
Refer to 3-6-2. Performing Backup for more information on the Backup procedure.
F3SG-SR
144
User's Manual
Upper
Upper
Lower
Lower
Lower
Fig. 1
Fig. 2
Status
OFF
illuminated
Area blocked by
blocking object is
illuminated in red
Upper
Upper
Upper
Upper
Lower
Lower
Fig. 3
Teach-in setting is invalid
LED Indicator
SEQ
Blinking
CFG
Blinking
Area blocked by
ABI
blocking object is
illuminated in red
Upper
Upper
Lower
Lower
Lower
Fig. 4
Fig. 5