Standard Muting Mode/Exit-Only Muting Mode With Reset Switch Connector - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Input/Output Circuit and Applications

6-2-2-4. Standard Muting Mode/Exit-Only Muting Mode with Reset Switch Connector

[Wiring Example]
F39-JG C-L
S1
Function
EDM
Interlock *6
Operating Range
Selection
Standard Muting Mode
Exit-Only Muting Mode *6
External Test used
Optical Synchronization
Timing chart
Beam state: Unblocked
Blocked
Test switch (S1)
Reset switch (S2)
MUTE A
MUTE B
OSSD
• When using the Reset Switch Connector (F39-GCNY3), the following functions are not available.
- External Device Monitoring (EDM)
• When a functional earth is necessary, wire an earth cable according to the example in 6-2-1-1. Auto Reset Mode with
Optical Synchronization and EDM Unused. Also refer to 5-4-4. Functional Earth Connection for more information.
F3SG-SR
330
User's Manual
XS5F-D421 80-F
L1
S2
DIP switch
EDM Disabled (factory default setting)
Manual Reset
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Long *6
N/A
N/A
Connect the TEST line of the emitter to 24V/0V via a test switch (NO contact). *7
N/A
Open the COM(+) and COM(-) lines of the emitter.
F39-JGR3K-D
F39-GCNY3
F39-JG A-D
S3
S4
*5
IN1
IN2
Safety controller
*3 *4
Setting
SD Manager 3
[Start interlock] : Enable
[Restart interlock] : Enable
[Operating Range Selection] : Long mode *6
[Muting] : Enable
[Muting mode] : Standard Muting (Installation Example 1/2) *6
[Muting] : Enable
[Muting mode] : Exit-Only Muting
[External test signal inversion] : Disable
S1: Test switch
S2: Lockout/interlock reset switch
S3: S4: Muting sensor
L1: Lamp
*1. Reverse the polarity of the power supply when using in the NPN
system. Select a safety controller of PNP or NPN type according to
the system of your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in
Short Mode.
*3. Refer to 6-3. Connectable Safety Control Units for more information.
*4. The safety controller and the F3SG-SR must share the power supply
or be connected to the common terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. Set the function with the DIP Switches on the Intelligent Tap or the
SD Manager 3, restore the settings to the F3SG-SR, and perform
wiring according to the wiring diagram.
*7. This is the example for the PNP system to stop emission when the
line is connected to 24 VDC and for the NPN to stop emission
when the line is connected to 0 VDC. If TEST switch is not
needed, refer to 2-6. External Test.
Intelligent Tap
Needed
Wiring for NPN *1
24 VDC
24 VDC
: Indicates a switch position