Setting with SD Manager 3
No.
6
Information assigned
7
Select unit of horizontal
axis
Reduced resolution zone is displayed in the Information assigned section only when the reduced resolution is enabled.

4-4-1-2. Operating Status Monitoring

This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
On the Top page, click the icon below.
The F3SG-SR enters detecting state, and the safety outputs are turned ON/OFF according to the beam state and
settings.
The screen below is displayed.
No.
1
External wiring status
2
Sensor Information
3
Operating Status
Monitoring
F3SG-SR
222
User's Manual
Function
Shows a function assigned to the beams. The following five functions can be assigned.
-Fixed blanking zone
-Floating blanking zone or Reduced resolution zone
-Warning zone
-Muting zone
Designated beam output zone
Switch the unit of the horizontal axis on the chart between the number of beams and
sensor length.
Function
Shows ON or OFF state of signal lines.
When DIP Switch Enabled is selected, it shows a state of DIP Switch settings. When
Configuration Tool Enabled is selected, it shows setting parameters saved in the F3SG-SR.
Shows the ON/OFF state of inputs and outputs of the F3SG-SR.
Shows Muting information, Override information, Sequence information, Safety output
information, Push-SW, and Blanking beam unblocked information.
Description