Connection Procedure When Using Usb Connector - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with SD Manager 3

4-1-3-2. Connection Procedure When Using USB Connector

1.
Connect the USB connector with the Intelligent Tap as follows.
2.
When you change the settings by using SD Manager 3, turn Positions 1 and 2 as shown below.
1
O
N
2
3
4
5
6
7
8
3.
Connect the USB connector with the PC's USB terminal.
When the Intelligent Tap is powered up, the OUT indicator of the Intelligent Tap is illuminated in red or
green.
Intelligent tap
4.
To restart the Intelligent Tap, unplug the USB connector from the Intelligent Tap and plug it again.
If the Intelligent Tap is connected with F3SG-SR, turn ON the external power supply connected with
the Intelligent Tap again.
After the Intelligent Tap restarts and the power is turned ON, the OUT indicator of the Intelligent Tap is
illuminated in red or green.
[Not connecting F3SG-SR]
F3SG-SR
164
User's Manual
TM
USB Type-C
• Position 1: ON (Lock)
• Position 2: OFF (DIP Switch Disabled)
: Indicates the switch position.
USB Type-C
TM
USB Type-C
TM
PC
[Connecting F3SG-SR]
Turn ON again
Power
supply