Area Beam Indicator (Abi) - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with SD Manager 3

4-3-3-3. Area Beam Indicator (ABI)

First, carry out 4-3-1. Preparing to Change Settings.
Next, on the Top page, click the icon below.
The setting screen below is displayed.
No.
Function name
1
Output
operation mode
of ABI
2
Output
operation mode
of ABI
3
Inverted signal
output of ABI
pattern
4
ABI output
pattern
F3SG-SR
200
User's Manual
Description
Select the operation mode of the area
beam indicator (ABI).
Items 2 to 4 below can be set only
when [Output Information] is
selected.
Select the information/signal
output by ABI.
Select Enable or Disable for the
inverted setting of ABI patterns.
Select an ABI output pattern.
Initial value
Configurable value or numerical range
Block/Unblock
Disable/Block/Unblock Information/
Information
Input signal linkage/Output information
Safety output
Red
information
ABI, refer to Information (Output
Stable-state
operation mode) assigned to Auxiliary
Orange
information
output of 4-3-3-1. Auxiliary Output.
Safety output
Green
information
Red
Enable
Enable/Disable
Orange Enable
Green
Disable
Red
Solid-ON
Illuminate/ON once/ON twice/ON three
times
Orange ON 1 time
Green
Solid-ON
For the information assigned to

Advertisement