2-13-3-2. Installation Example of Exit-Only Muting Mode

This is an installation example of the Exit-Only Muting mode. When using the Exit-Only Muting mode,
install the muting sensors on the hazardous side of the workpiece exit.
This can be used if a workpiece has a certain length and the hazardous side of the workpiece exit has
enough space around it.
1.
Before a workpiece passes through
All muting sensors are turned OFF and the safety function of the F3SG-SR is working.
2.
MUTING started
When the muting sensors A1 and B1 are turned ON in this order, and the MUTING state is enabled. In
this state, the safety function of F3SG-SR is disabled.
NPN
+24 VDC
S2
F3SG-SR
receiver
0V
Hazardous zone
A1 B1
F3SG-SR
Workpiece
V
d1
d2
Hazardous zone
A1 B1
F3SG-SR
Workpiece
System Operation and Functions
24V/0V (Brown)
S1
S2
MUTE B/
COM(-) (Pink)
MUTE A/PRE-RESET/PSDI/COM(+)
(Gray)
0V/24V (Blue)
A1 : Muting sensor to be connected
to muting input A
B1 : Muting sensor to be connected
to muting input B
d1: Distance between A1 and B1
d2: Distance between A1 and F3SG-SR
V
0V
+24 VDC
F3SG-SR
User's Manual