Ms48 Conversion Cable - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Wiring and Installation

5-4-3-9. MS48 Conversion Cable

Used to convert the wiring for MS4800 Safety Light Curtain to that for the F3SG-SR.
Do not connect the Conversion Cable for the following purposes. Failure to do so may result in failure.
1. Connecting with the F39-SGIT-IL3, F39-GCNY2 or F39-GCNY3
2. Connecting between the F3SG-SR's
Conversion Cables are only for PNP connection. To use for NPN, connect the 24 VDC line and the 0 VDC line in reverse.
There are the restrictions on the functions related to wiring when using Conversion Cables.
 MS48 Conversion Cable for Emitter (F39-JGR3K-MS-L, sold separately)
2-M2.5 screw
31.6
<Internal wiring diagram>
Connected to connector of MS4800 transmitter cable
1
0 VDC
2
+24 VDC
3
Not used
4
Not used
5
Not used
 MS48 Conversion Cable for Receiver (F39-JGR3K-MS-D, sold separately)
2-M2.5 screw
31.6
<Internal wiring diagram>
Connected to connector of MS4800 receiver cable
1
+24 VDC
2
0 VDC
3
Not used
4
OSSD 2
5
Start or EDM (Mode Select)
6
EDM
7
Auxiliary Out
8
OSSD 1
F3SG-SR
302
User's Manual
16.4
Connector
MS4800
16.4
Connector
MS4800
300
M12 IP67 connector, 5-wire
Oil-resistant PVC-insulated round cable, dia. 6
minimum bending radius R5
(Cross section of conductor: 0.2 mm
Male
300
M12 IP67 connector, 8-wire
Oil-resistant PVC-insulated round cable, dia. 6
minimum bending radius R5
(Cross section of conductor: 0.2 mm
Male
(Unit: mm)
44.7
2
/insulator diameter: dia. 1.1 mm)
(Unit: mm)
44.7
2
/insulator diameter: dia. 1.1 mm)