Monitoring With Sd Manager; Monitoring; Incident Light/Ambient Light - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

4-4. Monitoring with SD Manager 3

4-4-1. Monitoring

Logging in is not needed to perform the monitoring functions described in this section.

4-4-1-1. Incident Light/Ambient Light

This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
On the Top page, click the icon below.
The screen below is displayed.
No.
Function
1
Select light level
monitoring function
2
No. of beams to be
displayed
3
Show/hide held peak and
bottom hold
4
Select unit of vertical axis
5
ON/OFF threshold values
Select incident light level or ambient light level to be monitored and chart or list view.
Select the number of F3SG-SR beams to be displayed.
Shows the maximum and minimum values of a selected light level by light blue and pink
lines, respectively when [Show] is selected.
Switch the unit of the vertical axis on the chart between Percent and Level. When [Percent]
is selected, the light level is shown in percentage based on the ON threshold value as
100%. When [Level] is selected, the light level is converted to voltage.
Shows the ON and OFF threshold values of the F3SG-SR.
This information is only shown when the [Level] view is selected for the unit of vertical axis.
Setting with SD Manager 3
Description
E
F3SG-SR
221
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series