Setting with SD Manager 3
For more information on auxiliary output, refer to 2-12. Auxiliary Output.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor]
 Information (Output operation mode) assigned to Auxiliary output
Safety output information
Interlock information
Lockout information
Excess power-on time information
Excess load switching frequency information
Stable-state information
Muting information
Override information
Muting/Override information
Light level diagnosis information
Warning zone information
Blanking bream unblocked information
PSDI Information
Troubleshooting support signal
Designated beam output information
Sequence error information
Reset-input information
Mute A input information
Mute B input information
EDM input information
Individual cascaded sensor output (Channel 1)
Individual cascaded sensor output (Channel 2) *2 When Safety output of 1st Secondary sensor in cascade connection is the ON state
Individual cascaded sensor output (Channel 3) *2 When Safety output of the 2nd Secondary sensor in cascade connection is the ON state
Blanking/Warning-zone information
Instantaneous block information
Pre-reset Information
Communication quality diagnosis information
Recoverable error information
Replacement-recommended error information
None (OFF)
*1. This parameter can be changed using SD Manager 3. For details, refer to 4-3-5-2. Stable Light Threshold Adjustment.
*2. The function can be configured even when no secondary sensor (Channel 2 or Channel 3) is connected. In that case, the
safety outputs of the secondary sensor (Channel 2 or Channel 3) are regarded as the OFF state.
F3SG-SR
196
User's Manual
button.
Information Name
When Safety output is in the ON state
Under INTERLOCK state
Under error/ LOCKOUT state
When power-on time exceeds power-on time threshold
When load switching frequency exceeds load switching frequency threshold
When light intensity, which is constantly monitored, is 170% or higher
(changeable *1) of ON-threshold
Under Muting state
Under Override state
Under either Muting or Override state
When the F3SG-SR is unblocked and light intensity is within a range from 100%
to 170% of ON-threshold for 10 s or longer
When warning zone is blocked
When Fixed-Blanking or Floating Blanking beams are unblocked
When the F3SG-SR is ready to be blocked for feeding or removing parts
When one of the signals of Sequence error information, Interference/vibration
information and Light level diagnosis information is in the ON state.
When a designated beam is blocked or unblocked
Under Muting sequence error state or Interlock sequence error state
When Reset/EDM/Override input is in the ON state
When muting input A is in the ON state
When muting input B is in the ON state
When EDM signal input is in the ON state
When Safety output of Primary sensor in cascade connection is the ON state
When Fixed Blanking, Floating Blanking, Reduced Resolution or Warning Zone
function is enabled
When the F3SG system stops accidentally due to interference or vibration. (In
case of cascade connection, when any of cascaded segments comes under
this condition.)
Under Pre-reset state
Under communication retry state due to noise or communication cable short-circuit
Under recoverable error state
Under replacement-recommended error state
Disables the function.
Description