3-6-4. Various Usage of Backup and Restoration

3-6-4-1. Plug and Work

If the F3SG-SR with the Intelligent Tap installed causes a fault, its settings can be reconfigured only by
replacing with a new F3SG-SR of the same model and turning its power ON.

3-6-4-2. Copy and Paste of Sensor Settings

You can configure the same settings to multiple F3SG-SR's by configuring one F3SG-SR, performing
the Backup to an Intelligent Tap, and restoring the settings to other F3SG-SR's.

3-6-4-3. Changing F3SG-SR Configuration to Connect to Intelligent Tap

If you want to change an F3SG-SR's configuration to connect to an Intelligent Tap or if you want to
connect the Intelligent Tap to another F3SG-SR, perform the Backup of the settings of the newly
connected F3SG-SR first.

3-6-4-4. Changing F3SG-SR's Settings with Intelligent Tap DIP Switch

To change the F3SG-SR's settings only by setting the DIP Switch on the Intelligent Tap without using
the SD Manager 3, follow the steps below.
1. If the light curtain is under operation while the Intelligent Tap is already connected
(1) Make sure the power is OFF.
(2) Make sure that the DIP Position 1 is set at ON (Lock), and set the Position 2 at ON (DIP Switch
Enabled).
(3) Configure other functions with the DIP Switch Positions 3 to 8.
(4) After restart, restoration is performed.
(5) When the Restoration is complete, the OUT indicator (green) blinks fast. Restart the F3SG-SR.
2. To reflect the DIP Switch settings to an F3SG-SR that has no Intelligent Tap connected
(1) Connect an Intelligent Tap to the F3SG-SR.
(2) Turn the power ON. Refer to "3-6-2. Performing Backup" for the procedure of the Backup.
(3) Perform the steps from (1) to (4) of the procedure No. 1 above.
(4) After the Restoration is complete, turn the power OFF and disconnect the Intelligent Tap.