Follow the flowchart below to perform the Restoration.
Restoration
Power OFF
Activate settings by
DIP Switch on
Intelligent Tap?
No
Set DIP Switch Position 1on
Intelligent Tap at ON (Lock)
and Positions 2 to 8 at OFF
Connect Intelligent Tap to
F3SG-SR
Power ON
Intelligent Tap OUT indicator
blinks
Actual sensor configuration
corresponds with that in
Intelligent Tap?
Yes
(1)
Perform Restoration
(copying settings from
Intelligent Tap to F3SG-SR)
Yes
Restoration
successful?
Intelligent Tap OUT indicator
blinks fast
Yes
Set DIP Switch Position 1 on
Intelligent Tap at ON (Lock),
Position 2 at ON (DIP Switch
Enabled) and set Positions 3 to 8
according to your application
All F3SG-SR indicators other thanABI or
TOP/BTM indicator blink sequentially.
No
Only # of beams unmatched,
other configuration
information matched
Yes
Press and hold
Push Switch for
No
over 1 sec
Yes
(2)
No
Intelligent Tap OUT indicator
blinks fast and ERR indicator
lights up
Turn OFF power and disconnect
Intelligent Tap from F3SG-SR
End
Setting with Intelligent Tap
No
If the sensor configuration of
other than the number of
beams is not the same,
perform the Backup of the
connected F3SG-SR and
then perform the Restoration
again.
Intelligent Tap IN indicator
blinks fast, OUT indicator
blinks fast, and ERR
indicator lights up
E
F3SG-SR
139
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series

Table of Contents