Standard Muting Mode/Exit-Only Muting Mode With Y-Joint Plug; Joint Plug - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Input/Output Circuit and Applications

6-2-2-2. Standard Muting Mode/Exit-Only Muting Mode with Y-Joint Plug

F3SG-SRA
F3SG-SRB
[Wiring Example (F3SG-SR and F3SG-PGA-A/-L)]
F39-JGR3K-L and
F39-JG
B-L
PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.)
A1, A2, B1, B2: Muting sensor (E3Z-R†6)
Function
EDM
Interlock
Operating Range Selection Long (factory default setting)
Standard Muting Mode
Exit-Only Muting Mode
External Test not used
Optical Synchronization
Timing chart
Unblocked
Blocked
MUTE A
MUTE B
OSSD
• When using the Y-Joint Plug/Socket Connector (F39-GCNY2), the following functions are not available.
- External Test
- Operating Range Selection
- Wired Synchronization
• When a functional earth is necessary, wire an earth cable according to the example in
Synchronization and EDM Unused
F3SG-SR/PG
396
User's Manual
F3SG-PGA-A/-L
F3SG-PGA-C
F39-JGR3K-D and
F39-JG
B-D
F39-GCNY2
1
2
IN
IN1
IN2
Safety controller
PLC *2
*3 *4
DIP switch
EDM Disabled (factory default setting)
-
Auto Reset (factory default setting)
-
When not using the Intelligent Tap or the SD Manager 3, perform wiring according to the wiring diagram.
N/A
N/A
N/A
Connect the wires according to the diagram above.
*1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC
and a safety controller of PNP or NPN type according to the system of your application.
*2. When connecting to the PLC, the output mode must be changed with the SD Manager 3
according to your application. Refer to Chapter 4 Setting with SD Manager 3 for more
information on setting this function by the SD Manager 3.
*3. Refer to 6-3. Connectable Safety Control Units for more information.
*4. The safety controller and the F3SG-SR/PG must share the power supply or be
connected to the common terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. When using the Exit-Only Muting, set the function with the SD Manager 3, restore the
settings to the F3SG-SR, and perform wiring according to the wiring diagram.
. Also refer to 5-4-4. Functional Earth Connection for more information.
Intelligent Tap
2
Reflector
B1
Emitter
B2
A1
Reflector
Receiver
Reflector
1
Wiring for NPN *1
24 VDC
*5
Setting
SD Manager 3
[External device monitoring] : Disable *6
[Start interlock] : Disable
[Restart interlock] : Disable *6
[Muting] : Enable
[Muting mode] : Standard Muting (Installation
Example1/2) *6
[Muting] : Enable
[Muting mode] : Exit-Only Muting *6
6-2-1-1. Auto Reset Mode with Optical
Needed
Reflector
(E39-R1S)
A2
24 VDC