Setting Floating Blanking By Teach-In - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with Intelligent Tap

3-7-2. Setting Floating Blanking by Teach-in

 Overview
You can teach-in the settings of the Floating Blanking by interrupting with an object to monitor by the
Floating Blanking. The Teach-in described in this chapter is performed with the Intelligent Tap
connected to the F3SG-SR and using the Push Switch or the Muting Input A.
 Teach-in steps
Perform the Teach-in of the Floating Blanking based on the following steps.
(1) Connect Intelligent Tap to F3SG-SR
(2) Beam Alignment
(3) DIP Switch Setting
(4) Transition to Teach-in Mode
(5) Result Check Process
(6) Restart
(1) Connect Intelligent Tap to F3SG-SR
Connect the Intelligent Tap to the F3SG-SR.
(2) Beam Alignment
Perform the beam alignment for the F3SG-SR . In the case of the Optical Synchronization, install the
F3SG-SR so that the synchronization beams are clear.
For detailed beam adjustment steps, see 5-3-5. Beam Alignment Procedure.
Misalignment during the Teach-in may result in an unintended setting or a failure of the Teach-in.
The factory default setting of the Teach-in Input is [Push Switch]. When selecting [Push Switch or external wiring], select
[Teach-in Input] – [Push Switch or external wiring] with the SD Manager 3 after the step (2), and then perform the
Restoration.
Refer to 4-3-2-3. Teach-in Input for more information on setting this function by the SD Manager 3.
Refer to 4-2-7-3. Writing Configuration into Intelligent Tap for more information on the Restoration by the SD Manager 3.
(3) DIP Switch Setting
Before powering the F3SG-SR, set the DIP Switch Position 1 at ON (Lock), Position 2 at ON (DIP
Switch Enabled) and Position6 at OFF and 7 at ON (Floating Blanking Enabled). And then power the
F3SG-SR.
The Intelligent Tap restores the settings configured by the DIP Switch, to the F3SG-SR. When the
Restoration process is complete is completed successfully, restart the F3SG-SR and check if the
F3SG-SR operates normally.
Block the target Floating Blanking zone by an object. Do not remove the object until the Step (5) is
complete.
The object must be no smaller than the object resolution.
Refer to 3-4. LED Indicators on Intelligent Tap for more information.