System Operation and Functions
 Detection capability
Detection capability for the F3SG-SR differs based on the number of floating beams as shown below.
Model
F3SG-SR-14
F3SG-SR-25
F3SG-SR-45
F3SG-SR-85
 LED indicator status
When the Reduced Resolution is being enabled, the CFG indicator turns on.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
2-17-2. Factory Default Setting
Reduced Resolution is disabled.
2-17-3. Setting with Intelligent Tap
The user cannot make any changes to the settings of this function by DIP Switch on the Intelligent Tap.
F3SG-SR
102
User's Manual
Number of blocked
Detection capability
beams configured
-
14 mm
1 beam
24 mm
2 beams
34 mm
3 beams
44 mm
-
25 mm
1 beam
45 mm
2 beams
65 mm
3 beams
85 mm
-
45 mm
1 beam
85 mm
2 beams
125 mm
3 beams
165 mm
-
85 mm
1 beam
165 mm
2 beams
245 mm
3 beams
325 mm
Maximum diameter
Number of blocked
that does not turn off
beams to turn safety
the safety outputs in
outputs OFF
the detection zone
1 beam
2 beams
3 beams
16 mm
4 beams
26 mm
1 beam
2 beams
15 mm
3 beams
35 mm
4 beams
1 beam
2 beams
35 mm
3 beams
75 mm
4 beams
115 mm
1 beam
2 beams
75 mm
3 beams
155 mm
4 beams
235 mm
-
6 mm
-
55mm
-
-