Omron F3SG-SRB Series User Manual page 282

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Wiring and Installation
Height of
hazardou
s zone, a
2600
2500
2400
2200
2000
1800
1600
1400
1200
1000
800
600
400
200
0
Note 1. Upper edge of the detection zone below 900 mm is not included since they do not offer sufficient protection against
circumventing or stepping over.
Note 2. When determining the values of this table, it shall not be interpolated. If the known values a, b or Cro are between two
values of this table, the greater safety distance shall be used.
[Calculation example]
• T: Tm + Ts (s)
• Tm: Machine's response time (s)
• Ts: Response time of the F3SG-SR from ON to OFF (s)
• a: Height of machine hazardous zone (mm)
• b: Height of upper edge of detection zone (mm)
When Tm = 0.05 s, Ts = 0.008 s, a = 1,400 mm, b = 1,500 m:
From the table above, Cro = 850 mm. Since b is between 1,400 mm and 1,600 mm, b = 1,400
mm which has the greater Cro value, shall be used.
S = 2,000 mm/s × (0.05 s + 0.008 s) + 850 mm
= 966 mm
Since 966 mm is greater than 500 mm, use K = 1,600 mm/s and recalculate it.
S = 1,600 m/s × (0.05 s + 0.008 s) + 850 mm
= 942.8 mm
Compare S = 942.8 mm with the calculation for Detection Zone Orthogonal to Direction of
Approach, and choose the larger value as the safety distance.
For the system with a detection capability of 40 mm max., the safety distance S is 942.8 mm
since this is larger than S = 116 mm calculated in the calculation example of n Detection Zone
Orthogonal to Direction of Approach.
For the system with a detection capability larger than 40 mm, the safety distance S is 942.8 mm
since this is the same value as S = 942.8 mm calculated in the calculation example of Detection
Zone Orthogonal to Direction of Approach.
F3SG-SR
254
User's Manual
900
1000
1100
1200
0
0
0
0
400
400
350
300
550
550
550
500
800
750
750
700
950
950
850
850
1100
1100
950
950
1150
1150
1100
1000
1200
1200
1100
1000
1200
1200
1100
1000
1200
1150
1050
950
1150
1050
950
800
1050
950
750
550
900
700
0
0
600
0
0
0
0
0
0
0
Refer to Detection Zone Orthogonal to Direction of Approach under 5-1-2-1. Safety Distance Formulas according
to ISO 13855/EN ISO 13855.
Height of upper edge of detection zone, b
1300
1400
1600
Additional distance to hazardous zone, Cro
0
0
0
300
300
300
450
450
400
650
650
600
800
750
700
850
800
750
900
850
750
900
850
650
850
800
0
750
700
0
500
450
0
0
0
0
0
0
0
0
0
0
0
0
0
1800
2000
2200
2400
0
0
0
0
300
250
150
100
400
300
250
100
550
400
250
0
550
400
0
0
550
0
0
0
450
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0