If the Intelligent Tap is under the factory shipment status, the Backup will be automatically performed even if
DIP Switch Position 1 is set at ON (Lock) as it has no backup data in it. Unlike the normal Backup, you do not
have to operate the Push Switch nor restart the device after the end of the Backup.
The Backup saves the F3SG-SR's setup information in the Intelligent Tap which is automatically restarted and
performs its normal operation.
 LED indication during Backup
Mode
Transitioning modes
Waiting for Push Switch operation
Backup
Transferring data
Waiting for restart after Backup
Waiting for restart due to
communication error
Function
State
Setting with Intelligent Tap
Indicator
IN
OUT
(Yellow)
(Green/Red)
Illuminated
OFF
IO-Link
ERR
(Green)
(Red)
--
Fast
Slow
blinking
blinking
F3SG-SR