System Operation and Functions
 Timing chart
Muting sensor A1
Muting sensor B1
Muting sensor B2
Muting sensor A2
MUTING state
ABI indicator
Beam state
OSSD
 Reference: Preventing light interference of muting sensor
When a photoelectric sensor is used as a muting sensor, light interference may cause a muting error of
the F3SG-SR.
The cause and measures for light interference are shown as follows:
Reflected light
F3SG-SR
A1 B1
(1)
(1) Interference between muting sensors
• Use sensors with mutual interference prevention (such as retro-reflective E3Z-R series)
• Use laser-type sensors (such as laser-type E3Z-LR series)
• Take distance from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them
crosswise)
• Install a physical barrier
• Attach interference prevention filter (provided for E3Z series as accessories)
• Attach a slit to reduce light intensity (provided for E3Z series as accessories)
• Lower the sensitivity
F3SG-SR
72
User's Manual
T3 (0.1 s) max.
ON
OFF
T1min to T1max
ON
OFF
ON
OFF
ON
OFF
80 ms max. *
Enabled
Disabled
Orange
ON
blinking
OFF
Unblocked
Blocked
ON
OFF
* 102 ms max. when the
Intelligent Tap is connected
to the F3SG-SR.
B2
A2
A1 B1
Workpiece
(1)
T3 (0.1 s) max.
T3 (0.1 s) max.
T3 (0.1 s) max.
T2 max.
Green blinking
T1min: Muting input time limit value (minimum)
T1max: Muting input time limit value (maximum)
T2: Muting time limit
T3: Maximum allowable muting signal interruption
Direct light
F3SG-SR
B2 A2
Workpiece
(1)
(1)
Orange
blinking
Light from other F3SG-SR
F3SG-SR
A1 B1
B2 A2
Workpiece
(2)
(3)
D