Standard Muting mode
Muting zone
T1
: Muting input time limit value (minimum)
min
T1
: Muting input time limit value (maximum)
max
T2: Muting time limit
T3: Maximum allowable muting signal interruption
Exit-Only Muting mode
Muting zone
T1
: Muting input time limit value (minimum)
min
T1
: Muting input time limit value (maximum)
max
T2: Muting time limit
T3: Maximum allowable muting signal interruption
T4: Muting end wait time
T5: Exit-only muting delay time
Position Detection Muting mode
Muting zone
T1
: Muting input time limit value(maximum)
max
T2: Muting time limit
T3: Maximum allowable muting signal interruption
Dynamic Muting
Dynamic muting
Dynamic muting measurement time
Number of dynamic muting allowable beams
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the muting time limit to infinite may cause a failure of the muting sensors to go undetected, resulting in the F3SG-SR
in an unintended MUTING state. Conduct risk assessment analysis thoroughly before enabling this setting.
Setting the muting input time limit value (maximum) to infinite may cause a failure of the muting sensors to go
undetected, resulting in a failure of disabling the MUTING state. Conduct risk assessment analysis thoroughly before
enabling this setting.
Dynamic Muting can be used in conjunction with any of Standard, Exit-Only and Position Detection Muting modes.
Refer to Chapter 4 Setting with SD Manager 3 for more information on setting this function by the SD Manager 3.
F3SG-SR
84
User's Manual
Function
Bottom beam
All beams
Top beam
0.1 s
4 s
60 s
0.1 s
Function
Bottom beam
All beams
Top beam
0.1 s
4 s
60 s
0.1 s
1 s
4 s
Function
Bottom beam
All beams
Top beam
4 s
60 s
0.1 s
Function
Disable
3 s
1
Initial value
Configurable value or numerical range
any beam in 1-beam increments
0.1 to 3.9 s in 0.1-s increments
0.2 to 60 s in 0.1-s increments, or infinite
1 to 600 s in 1-s increments, or infinite
0.1 to 20 s in 0.1-s increments
Initial value
Configurable value or numerical range
any beam in 1-beam increments
0.1 to 3.9 s in 0.1-s increments
0.2 to 4 s in 0.1-s increments, or infinite
1 to 600 s in 1-s increments, or infinite
0.1 to 4 s in 0.1-s increments
0.1 to 20 s in 0.1-s increments
4 to 20 s in 0.1-s increments
Initial value
Configurable value or numerical range
any beam in 1-beam increments
0.2 to 60 s in 0.1-s increments, or infinite
1 to 600 s in 1-s increments, or infinite
0.1 to 4 s in 0.1-s increments
Initial value
Configurable value or numerical range
Enable/Disable
1 to 25 s in 0.1-s increments
0 to 5 in 1-beam increments