Setting with Intelligent Tap

3-6-3. Performing Restoration

When perforning the Restoration, make sure to set the DIP Switch Position 1 at ON
(Lock) before turning on the power. If the DIP Switch Position 1 at OFF (Unlock), the
Backup is performed, which may cause the settings of the Intelligent Tap to be
overwritten and a person to go undetected, resulting in serious injury.
When the Restoration is performed, if the DIP Switch Position 2 is at ON (DIP Switch
Enabled) and settings of the DIP Switch Positions 3 to 8 are different from the backup
data in the F39-SGIT-IL3, the settings in the DIP Switch takes priority and are saved in
the F3SG-SR. To prevent such an accident, it is recommended that you set the DIP
Switch Position 2 at OFF before performing the Restoration when you use the settings
backed up from the F3SG-SR or make settings with the SD Manager 3.
• When performing the Restoration of the backup data saved in the Intelligent Tap to the F3SG-SR, if the DIP Switch
Position 2 is set at ON (DIP Switch Enabled) and the Positions 3 to 8 are set to different functions from the settings of
the backup data, the settings of the DIP Switch will be restored to the F3SG-SR. When you want to change the settings
of the F3SG-SR to the backup data in the Intelligent Tap, change the DIP Switch Position 2 to OFF (DIP Switch
Disabled) and then perform the Restoration again.
• If the DIP Switch Position 1 is set at ON (Lock) and settings in the Intelligent Tap corresponds with that in the sensor,
restoration is not performed.