4-3-4-2. Floating Blanking

First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
No.
Function name
1
Floating Blanking
Setting
2
Zone Adjustment Automatically adjusts a floating blanking zone setting when the
3
Floating blanking
monitoring
4
Temporarily
Disable
Monitoring
For more information on the Floating Blanking, refer to 2-16. Floating Blanking.
If using this function together with other functions, make settings taking the condition of adjacent zones into account.
For more information on zone adjacency conditions, refer to 2-19. Setting Zone Adjacency Conditions.
Description
Select Enable or Disable for the Floating Blanking function.
setting is not correct.
Set the floating blanking
monitoring, number of floating
beams, and number of allowable
beams.
Select Enable or Disable for the
Temporarily Disable Monitoring
function and configure the
Monitoring-temporarily-disabled
time limit.
Setting with SD Manager 3
Initial
value
Disable
-
Floating blanking
Lockout
monitoring
Number of floating
1
beams
Number of allowable
0
beams
Temporarily disable
Disable
monitoring
Monitoring temporarily
10 s
disabled time limit
Configurable value or
numerical range
Disable/Enable
-
Disable monitoring /
Lockout/ Cancel
blanking Zone
1 to 15 beams
(in 1-beam increments)
0 to 5 beams
(in 1-beam increments)
Disable/Enable
0 to 200 s
(in 1-s increments)
(Infinite when 0 is set)
F3SG-SR
205
User's Manual