The table below lists the data size and descriptions of the process data items.
Name
Power supply voltage
Sequence error information
Light level diagnosis information
(Channel 1)
Light level diagnosis information
(Channel 2)
Light level diagnosis information
(Channel 3)
Instantaneous Block Detection
Information (Channel 1)
Instantaneous Block Detection
Information (Channel 2)
Instantaneous Block Detection
Information (Channel 3)
Safety output status
Auxiliary output status
Mute A input status
Mute B input status
RESET/EDM/Override input status
Intelligent Tap Lockout information
Sensor or Intelligent Tap lockout
information
Reserved
* It is necessary to change the value in the setting of [Stable Light Threshold Adjustment] of the SD Manager 3.
Refer to 2-24. Stable Light Threshold Adjustment and 4-3-5-2. Stable Light Threshold Adjustment for more information on the
stable light threshold value.
Data size
16 bits
Power supply voltage value for Receiver being supplied. (VDC)
1 bit
1: Under muting sequence error state or interlock sequence error state.
0: No muting sequence error state or interlock sequence error state.
1 bit
1: When the single F3SG-SR or the primary sensor in cascaded
connection is unblocked and light intensity is within a range from 100%
to 170% (factory default setting*) of ON-threshold for 10 s or longer.
0: When the single F3SG-SR or the primary sensor in cascaded
connection is blocked and light intensity is lower than 100% of ON-
threshold for 10 s or longer.
1 bit
1: When the 1st secondary sensor in cascaded connection is unblocked
and light intensity is within a range from 100% to 170% (factory default
setting*) of ON-threshold for 10 s or longer.
0: When the 1st secondary sensor in cascaded connection is blocked
and light intensity is lower than 100% of ON-threshold for 10 s or
longer.
1 bit
1: When the 2nd secondary sensor in cascaded connection is unblocked
and light intensity is within a range from 100% to 170% (factory default
setting*) of ON-threshold for 10 s or longer.
0: When the 2nd secondary sensor in cascaded connection is blocked
and light intensity is lower than 100% of ON-threshold for 10 s or
longer.
1 bit
1: When the single F3SG-SR or the primary sensor in cascaded
connection stops accidentally due to instantaneous blocking.
0: When the single F3SG-SR or the primary sensor in cascaded
connection is not blocked.
1 bit
1: When the 1st secondary sensor in cascaded connection stops
accidentally due to instantaneous blocking.
0: When the 1st secondary sensor in cascaded connection is not
blocked.
1 bit
1: When the 2nd secondary sensor in cascaded connection stops
accidentally due to instantaneous blocking.
0: When the 2nd secondary sensor in cascaded connection is not
blocked.
1 bit
1: ON, 0: OFF
1 bit
1: ON, 0: OFF
1 bit
1: ON, 0: OFF
1 bit
1: ON, 0: OFF
1 bit
1: ON, 0: OFF
1 bit
1: Intelligent Tap is in LOCKOUT state
0: Intelligent Tap is not in LOCKOUT state.
1 bit
1: Sensor or Intelligent Tap is in LOCKOUT state
0: Nether the Sensor or Intelligent Tap is in LOCKOUT state.
4 bytes
0
Setting with Intelligent Tap
Description
F3SG-SR
User's Manual
E
153