Muting Using Pnp Outputs; Standard Muting Mode/Exit-Only Muting Mode Using Pnp Outputs - Omron F3SG-2RE0430P30 User Manual

Safety light curtain
Table of Contents

Advertisement

Input/Output Circuit and Applications

5-2-2. Muting using PNP Outputs

5-2-2-1. Standard Muting Mode/Exit-Only Muting Mode using PNP Outputs

The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output
and External Test in 24 V Active.
[DIP Switch settings] *6
Receiver
Emitter
Configure functions with the DIP Switches before wiring.
[Wiring Example]
S1: Test Switch (Connect the line to 0 V if this switch
is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch
or Override Cancel Switch
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to
the Reset line when using the override function.
Otherwise the override state may not be released by
the override cancel switch, resulting in serious injury.
*3. Refer to 5-4. Connectable Safety Control Units for
more information.
*4. The safety controller and the F3SG-R must share
the power supply or be connected to the common
terminal of the power supply.
*5. Refer to Smart Muting Actuator F3W-MA Series
User's Manual for more information.
*6. The functions are configurable with DIP Switch.
Refer to Chapter 3 Setting with DIP Switch for more
information on setting the functions by the DIP
Switch.
*7. When connecting to the PLC, the output mode must
be changed with the Configuration Tool according to
your application.
F3SG-R
196
User's Manual
Function
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
F39-JG A-L
S1
DIP-SW1
F39-JG A-D
S2
*2
IN
IN1
Muting
PLC *7
Actuator *5
Controller *3 *4
Unblocked
Beam state
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
DIP-SW2
: Indicates a switch position.
+24 VDC
Power Supply
0 VDC
IN2
Safety