Standard Muting Mode/Exit-Only Muting mode with Intelligent Tap

[Wiring Example]
F39-JG B-L/
XS5F-D521-DJ0-IL
IO-Link
Master * 7
F39-JG A-D
S1
S2
* 3
Function
EDM
Interlock
Operating Range Selection
Standard Muting Mode
Exit-Only Muting Mode
Test Input
Wired Synchronization
Timing chart
Beam state: Unblocked
Blocked
MUTE A
MUTE B
OSSD
Note: 1. When using the Intelligent Tap (F39-SGIT-IL3), the following functions are not available.
• External Test
• Operating Range Selection by wiring
• Optical Synchronization
2. For the functional earth connection, refer to page 66.
74
F39-SGIT-IL3
F39-JGR3K-L and F39-JG□B-L
S3
IN
IN1
IN2
Safety controller
PLC * 4
* 5 * 6
DIP switch
EDM Disabled
Auto Reset
Long
N/A
N/A
N/A
Connect the emitter and receiver with the Intelligent Tap.
F39-JGR3K-D and
F39-JG□B-D
Wiring for NPN * 1
24 VDC
* 8
Setting
[External device monitoring] : Disable
3
ON
4
ON
[Start interlock] : Disable
[Restart interlock] : Disable
5
ON
[Operating Range Selection] : Long mode
8
ON
[Muting] : Enable
[Muting mode] : Standard Muting (Installation
Example1/2)
[Muting] : Enable
[Muting mode] : Exit-Only Muting
S1: Lockout reset switch, override switch or override cancel switch
S2, S3: Muting sensor
PLC: Programmable logic controller (Used for monitoring only. NOT
related to safety system.)
*1. Reverse the polarity of the power supply when using in
the NPN system. Select a PLC and a safety controller of
PNP or NPN type according to the system of your
application.
*2. Also used as OVERRIDE INPUT line.
*3. Make sure to connect an override cancel switch to the
RESET line when using the override function. Otherwise
the override state may not be released by the override
cancel switch, resulting in serious injury.
*4. When connecting to the PLC, the output mode must be
changed with the SD Manager 3 according to your
application. For the setting this function, refer to the
User's Manual (Man.No.Z405).
*5. Refer to page 75 for more information.
*6. The safety controller and the F3SG-SR must share the
power supply or be connected to the common terminal of
the power supply.
*7. For connecting with the IO-Link Master unit, refer to an
instruction manual of the IO-Link Master unit you use.
*8. This is the case for a PELV circuit.
Intelligent Tap
Needed
24 VDC
 : Indicates a switch position.
SD Manager 3