Omron F3SG-SRB Series User Manual page 37

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

 Emitter (F3SG-SR)
Location Indicator
Name
C
1
Scan code
or
CODE
E
2
Lockout
or
ERR
L
Operating
3
or
range
LONG
T
4
Test
or
TEST
Area
Beam
5
-
Indicator
(ABI) (*1)
Top-beam-
6
TOP
state (*1)
Bottom-
7
BTM
beam-
state (*1)
*1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the
Optical Synchronization is enabled.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to "2-13. Muting".
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
*6. DIP switches is on the Intelligent Tap.
Color
Illuminated
Green
Code A is selected
Orange Code B is selected
Automatic interference
prevention by wired
OFF
synchronization being
performed
LOCKOUT state. The
indicator is illuminated in
the emitter of another
sensor segment than that
Red
having a lockout error
(when in cascade
connection or between the
emitter and receiver in the
Wired Synchronization)
Long Mode is selected
Green
Short Mode is selected
OFF
Yellow
-
The target beams of the
ABI are unblocked and
Green
the safety outputs are
turned ON
Incident light level of
the target beams of the
ABI is 170% (factory
default setting (*2)) or
less of ON-threshold
Orange
(for 5 to 10 s)
The target beams of the
Red
ABI are blocked
The target beams of the
ABI are unblocked (The
ABI then will be
OFF
illuminated in green
when the safety outputs
are turned ON.)
The top beam is
Blue
unblocked
The bottom beam is
Blue
unblocked
Overview and Specifications
Blinking
-
LOCKOUT state. The indicator is
illuminated in the emitter of a sensor
segment having a lockout error
LOCKOUT state due to Operating
range selection setting error
External Test is being performed
MUTING or OVERRIDE state. In the
MUTING state, only the ABI indicators
in the muting zone are blinking. Or the
target beams of the ABI are blocked
instantaneously
Incident light level of the target beams of
the ABI is 170% (factory default setting
(*2)) or less of ON threshold 5 to 10 s
after illuminated when incident light level
of the target beams of the ABI is 170%
(factory default setting (*2)) or less of ON
threshold. Or one muting input becomes
the ON state and the MUTING state has
not been started yet, or one muting input
becomes the OFF state and the other is
not in the OFF state yet. (*3)
LOCKOUT state due to Cap error or Other
sensor error (*4), or LOCKOUT state due
to DIP Switch setting error (*5 *6)
-
MUTING/OVERRIDE state, or
LOCKOUT state due to Cap error or
Other sensor error
MUTING/OVERRIDE, or LOCKOUT
state due to DIP Switch setting error (*6)
F3SG-
F3SG-
SRA
SRB
X
X
X
X
X
X
X
X
X
-
-
X
-
X
E
F3SG-SR
9
User's Manual