Setting with SD Manager 3

4-5-5. Monitoring with SD Manager 3

4-5-5-1. Incident/Ambient Light Level Monitoring

Tap the following icons on the main screen.
The screen below is displayed.
No.
1
Light level monitoring operation
2
Incident light/ambient light
switching
3
Peak and bottom holding
operation
4
Zone display
5
Beam display
6
Light level display
7
Function switching
F3SG-SR
242
User's Manual
Function name
Starts or stops monitoring of the selected function.
Select either incident light or ambient light as the monitoring target.
When setting the display, the maximum and minimum values of incident light are
displayed with a water-color and pink lines, respectively.
Displays the function assigned to the beam.
Each display means the following function.
• DS: Designated beam output zone
• MT: Muting zone
• WR: Warning zone
• FL: Floating blanking zone
or RR: Reduced resolution zone
• FX: Fixed blanking zone
Displays the beams of the F3SG-SR being monitored.
Displays the light level and ON/OFF threshold of the selected function.
The icon of the function which is being monitored is highlighted. Tapping the icon of
the other function switches to the display of the corresponding function.
Description