Omron F3SG-SRB Series User Manual page 39

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Location Indicator
Name
Area
Beam
8
-
Indicator
(ABI)
Top-beam-
9
TOP
state
Bottom-
10
BTM
beam-
state
*1. Refer to 8-1. Troubleshooting for more information on blinking patterns.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to 2-13. Muting.
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
*6. DIP switches is on the Intelligent Tap.
In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter
and the CFG, PNP and CODE indicators on the receiver blink.
(TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to
of F3SG-SR with SD Manager 3 Connected.
Color
Illuminated
The target beams of the
ABI are unblocked and
Green
the safety outputs are
turned ON
Incident light level of the
target beams of the ABI
is 170% (factory default
setting (*2)) or less of
ON-threshold (for 5 to 10
s)
Orange
The target beams of the
ABI are blocked
Red
The target beams of the
ABI are unblocked (The
ABI then will be
OFF
illuminated in green when
the safety outputs are
turned ON.)
The top beam is
Blue
unblocked
The bottom beam is
Blue
unblocked
Overview and Specifications
Blinking
MUTING or OVERRIDE state. In the
MUTING state, only the ABI
indicators in the muting zone are
blinking. Or the target beams of the
ABI are blocked instantaneously
Incident light level of the target
beams of the ABI is 170% (factory
default setting (*2)) or less of ON
threshold 5 to 10 s after illuminated
when incident light level of the target
beams of the ABI is 170% (factory
default setting (*2)) or less of ON
threshold. Or one muting input
becomes the ON state and the
MUTING state has not been started
yet, or one muting input becomes the
OFF state and the other is not in the
OFF state yet. (*3)
LOCKOUT state due to Cap error or
Other sensor error (*4), or LOCKOUT
state due to DIP Switch setting error
(*5 *6)
-
MUTING/OVERRIDE state, or
LOCKOUT state due to Cap error or
Other sensor error
MUTING/OVERRIDE state, or
LOCKOUT state due to DIP Switch
setting error (*6)
F3SG-
F3SG-
SRA
SRB
X
-
-
X
-
X
4-1-4. SETTING State
F3SG-SR
11
User's Manual
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series

Table of Contents