4.4.3.1 7-segment display controller

Refer to parameter manual for detailed description of drive states and state transitions.
0: Low, 1: High
State 
Display
drive manager
NOT READY TO SWITCH ON Drive message „Not ready for switching power on"
0
SWITCH-ON INHIBIT
1
READY TO SWITCH ON
2
SWITCHED ON
3
OPERATION ENABLED
4
BETRIEB SPERREN AKTIV
5
OPERATION INHIBIT ACTIVE Pulse enable = 0
6
QUICK STOP ACTIVE
7
ERROR RESPONSE ACTIVE
E
ERROR
F
Parking axis
P
NOTE!
In addition the error No. is displayed, refer to
tion–
96
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
Meaning
Inhibit voltage, e.g. quick stop active
Drive shutdown
Control word: xxxx x110
Pulse enable = 0
Quick stop = 1 (low active)
Control word: xxxx x111
Pulse enable = 1
Quick stop = 1
Control word: xxxx 1111
Pulse enable = 1
Quick stop = 1
Quick stop = 0 (low active)
Error message
Reset via control word 0xxx xxxx
or reset stored errors 0
as from page 237.
1
ZBM51XX and BM53XX error detec-