Correction Values Input Voltage; Derating: Output Current As A Function Of The Power Supply Voltage - Baumuller b maXX 5000 Series Instruction Handbook Manual

Mains rectifier/ active mains rectifier. axis units safety
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

3.3
Operating conditions

3.3.5.3 Correction values input voltage

Above 
m Mains rectifier units BM503X, BM504X, BM517X, BM519X
rated power 
The rated power supply voltage is 3 x 400 V
supply voltage
The output currents must be reduced accordingly when operating with a power supply
voltage higher than 400 V.
Figure 21:
The device draws the rated/peak current at rated supply voltage. The input current must
be reduced if power supply voltage is higher than 400 V and the DC link output power re-
mains constant.
Figure 22:
52
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
100 %
50 %
180 V

Derating: Output current as a function of the power supply voltage

Supply voltage [V]
Derating: Input current BM503X, BM504X, BM517X, BM519X
400 V
528 V
Power supply voltage
Peak current
Max. continuous
current
Baumüller Nürnberg GmbH