Error Detection; Bm50Xx Error Detection; Bm51Xx And Bm53Xx Error Detection - Baumuller b maXX 5000 Series Instruction Handbook Manual

Mains rectifier/ active mains rectifier. axis units safety
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

10.3 Error detection

10.3.1 BM50XX error detection

The error state is signalized by the lighting up of the red LEDs H1 to H4 on the front side
of the housing.
The meaning of the individual LEDs is explained in
from page 90 for devices without safety function and
function–

10.3.2 BM51XX and BM53XX error detection

LED
The error state is signalized by the lighting up of the red LED H14 or H24 on the front side
of the housing.
The meaning of the individual LEDs is explained in
Essentially, the lowest red LEDs H14 and H24 „Malfunction" are of significance here.
NOTE!
In case of warnings or errors without error reactions, the LEDs H14 or H24 blink
„Malfunction". Only error messages with error reaction are signalized by constant
lighting up.
7-segment display In the status error the error numbers are shown in the display. Depending on the state of
bit No. 16 in parameter P135.1 (further information see parameter handbook b maXX
5000) all error messages (with/without error reaction) or warnings are displayed.
The display of an error code starts therewith, that „F" is displayed for 1.5 s. Then the four
characters of the error code are displayed. The separate characters are displayed for
about 0.8 s, interrupted by a short break. If there are other errors, these are displayed in
the same manner. The procedure is repeated as soon as all errors were displayed.
Example: Error 702 and 2418 are detected:
Start
Error
display
Figure 102:
For further information on the subjects of error messages and error numbers, see „Pa-
rameter manual b maXX 5000„.
Troubleshooting and Fault correction
as from page 306 for devices with safety function.
7-segment display: errors and warnings
ZDisplay and operating elements–
ZLED display BM5030 with safety
ZLED display controller–
End
Instruction handbook b maXX 5000
Document No.: 5.09021.16
10
as
on page 97.
Time
237
of 328

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm5100 seriesBm5300 seriesBm5000 seriesB maxx 5000B maxx 5100B maxx 5300

Table of Contents