9.1
Environmental condition
9.1
Environmental condition
If the prescribed environmental conditions are adhered to, then the device is mainte-
nance-free. For the prescribed environmental conditions, see
conditions–
The most important prescribed environmental conditions are:
m Dust-free environmental air
m Temperature:
m Relative humidity:
m Installation altitude:
9.2
Inspection intervals - maintenance notes
Preventive maintenance is prescribed to keep the device in an optimum operating condi-
tion and ensure a long service life. It is recommended to have inspections performed reg-
ularly by qualified personnel.
Daily
Basic check points as to whether discrepancies have occurred during operation:
inspection:
m Does the motor work as desired?
m Is the operating environment normal?
m Is the cooling system working normally?
m If an unusual vibration or noise is noticed during operation.
m Does the motor overheat during operation?
Regularly sched-
Before checking, switch off the input voltage and wait until the device's capacitors have
uled inspection:
discharged.
DANGER!
Risk of fatal injury from electrical current!
Therefore:
m Switch off voltage before performing work!
m Only qualified personnel may mount, install and maintain the devices.
m Please remove all metallic objects worn, such as watches or rings, for example,
m Only insulated tools are permitted.
222
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
on page 47.
Min. 5 °C to max. +55 °C
5% to 85%, no condensation
From 1000 m and higher derating
before beginning to work on the device.
ZRequired environmental
Baumüller Nürnberg GmbH