7-Segment Display Bm51Xx - Baumuller b maXX 5000 Series Instruction Handbook Manual

Mains rectifier/ active mains rectifier. axis units safety
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

4.4.2.1 7-segment display BM51XX

Refer to parameter manual for detailed description of drive states and state transitions.
0: Low, 1: High
State 
Display
drive manager
NOT READY TO SWITCH ON Device message „Not ready for switching power on"
0
SWITCH-ON INHIBIT
1
READY TO SWITCH ON
2
SWITCHED ON
3
OPERATION ENABLED
4
OPERATION DISABLED
6
QUICK DISCHARGE ACTIVE
7
ERROR
F
NOTE!
In addition the error No. is displayed, refer to
tion–
Meaning
Device disabled
Device shutdown
Control word: xxxx x110
Pulse enable = 0
Quick discharge = 0
Control word: xxxx x111
Pulse enable = 1
Quick discharge = 0
Control word: xxxx 1111
Pulse enable = 1
Quick discharge = 0
Pulse enable = 0
Quick discharge = 1 (high active)
Error message
Reset via control word 0xxx xxxx
or hardware input reset stored errors 0
as from page 237.
Design and Operation
ZBM51XX and BM53XX error detec-
Instruction handbook b maXX 5000
Document No.: 5.09021.16
4
1
93
of 328