Error handling

10.4 Error handling

10.4.1 Error acknowledgment of BM50XX

If the red error LEDs H1 to H4 light up, then at least one error has been detected.
All error messages are reset by error acknowledgment. Individual acknowledgment of er-
rors is not possible. An acknowledgment delete all errors, if deletion was possible on ac-
count of the error cause.
Errors can be acknowledged via the digital input X1:4. 
Thereby a rising edge (low to high) is evaluated. The high level has to be applied at least
100 ms.
BM50XX-XXX0
For further information, see
BM50XX-XXX1
For further information, see
238
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
NOTE!
The device is shipped with predefined error reactions. With regard to the error mes-
sages identified with „depending on the setting" in the „Reaction" column, the device's
error reaction can be adjusted. Error messages that, due to safety reasons, have an
immediate pulse inhibit as a consequence, may not be changed.
NOTE!
When using devices BM5XXX-XXX1 all error messages can be reset with
Power supply off
Power supply on additionally.
ZFigure 64–
on page 143 and
ZFigure 65–
on page 144 and
ZFigure 74–
on page 157.
ZFigure 74–
on page 157.