C.4
LED display BM5030 with safety function
C.4
LED display BM5030 with safety function
BM5030-XX2X-...
Figure 127:
306
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
LED
READY - Mains rectifier unit ready-to-operate:
H1
green:
Power supply and DC link voltage available, internally
OK
red:
Power supply failure - automatically restart when power
supply returns.
blinking red: Power supply failure longer than 10 s - restart after
Power supply return has to be acknowledged (X1:4).
Refer to
238)
LED
PHASE FAILURE
H2
red:
Phase failure
LED
OVERTEMPERATURE
H3
red:
Overtemperature
LED
DC-LINK ERROR
H4
red:
DC link error:
U
U
Inhibit input active
LED
STO POWER
H5
green:
U
DC
orange:
U
DC
red:
Error
LED
STO STATUS
H6
green:
Ready-to-operate
orange:
U
DC link
red:
STO error
Display/operating elements BM5030-XX2X-...
ZError acknowledgment of BM50XX–
overvoltage or
DC link
overcurrent or
DC link
is available
is not ready
charging procedure,
on page
Baumüller Nürnberg GmbH