Wiring Of The Power Cables - Baumuller b maXX 5000 Series Instruction Handbook Manual

Mains rectifier/ active mains rectifier. axis units safety
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

2.4
Risk assessment according EU Directive
Mounting
Unprotected hands can be injured at the sharp edges of the device.
m Wear safety gloves!
Unprotected eyes can be injured by thrown up metal particles caused by drilling or making
cut-outs.
m Wear safety glasses!
Short-circuit in
In case of a short-circuit high current flows. This current induces a magnetic field in cable
power cables
loops. The magnetic field can cause failures of the device.
To avoid additional damage in case of a short-circuit in power cables,
Figure 1:
Installation
If a shielded cable is connected unshielded and this causes failure of the device/danger
to persons, the system manufacturer is responsible for.
Brake resistor
The dissipation of the heat loss of the external brake resistor must be ensured.
connection
Communication
Ensure that a failure of the device will cause no danger to persons.
errors
The safety notes of all further chapters of this documentation need to be carefully ob-
served!
18
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
n The connection between power supply and device or between device and motor
must be laid without loop.
Motor cable or
power connection
Device

Wiring of the power cables

Motor cable or
power connection
Device
Baumüller Nürnberg GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm5100 seriesBm5300 seriesBm5000 seriesB maxx 5000B maxx 5100B maxx 5300

Table of Contents