11.1
Cabling
11.1.9.4 Connecting cable for encoder with EnDat
The connecting cable is available as accessory part with M12 or speedtec
Baumüller Nürnberg GmbH.
M12
Follow the instructions below if a self-made cable with M12 is to be used:
1 Utilize the following materials:
2 Fully adjoin the cable shield with the housing of the round connector and with the
Figure 111:
256
Instruction handbook b maXX 5000
Document No.: 5.09021.16
of 328
m Cable: 4x0,38 + 1x(4x0,14)
m High-density D-sub connector: 26-pin, male
m Round connector: 8-pin M12, female (e.g. from Interconnectron)
shielding of the D-sub connector.
Connecting cable for encoder with EnDat
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!
®
2.2
®
2.2 M12
®
M23 from
Baumüller Nürnberg GmbH